Test
The TGA/DSC 3+ provides trustworthy results using a TGA balance from the worldwide leader in weighing technology with position-independent weighing, automatic internal calibration weights, a wide measurement range, the best minimum weight performance and the highest weighing accuracy and precision.
Depth (English) | 24.8 in. |
---|---|
Warranty | 1 Year |
Width (English) | 21.3 in. |
Capacity | ≤900 μL |
Voltage | 115 V |
Length (English) | 24.8 in. |
Frequency | 50/60 Hz |
Certifications/Compliance | IEC/EN61010-1:2001 |
Sample Volume (Metric) | ≤900 μL |
Small furnace TGA that’s well suited for samples up to 100μL with a temperature range up to 1100°C. Includes a 6 place microgram balance.
The HS82 hot-stage system offers the best solution in all situations where the temperature of very small samples has to be regulated in a limited space and where the samples have to be observed at the same time. The system consists of a HS 1 control unit and a HS82 microscope hot stage.
Alumina Sample Cups, Disposable, 90 μL, SDT, 20/pk.
Hangdown wires suspend down from the TGA 8000 Furnace Balance Mechanism and catch a sample pan's hook and lift the pan from the Autosampler and into the furnace. The hangdown wires come in a variety of materials and kit sizes.
These wires ship standard with TGA analyzers. With this part number, these wires can be ordered separately to replenish your supplies.
NC1562674 PLATINUM SAMPLE PANS 50UL 3/PK
Stainless Steel Bail, TGA, 15/pk.
The Aluminum Sample Pans and Covers are used with nonvolatile solid samples, such as polymers and pharmaceuticals. They are routinely used for applications such as polymer melting, crystallization, glass transitions of polymers, thermoplastics, and thermosets. Pans are crimped but not hermetically sealed.
Hangdown wires suspend down from the TGA 8000 Furnace Balance Mechanism and catch a sample pan's hook and lift the pan from the Autosampler and into the furnace. The hangdown wires come in a variety of materials and kit sizes.
NC1956391 KAPTON HANGDOWN LOOP 10EA
Platinum Sample Pans, 100 iL (pkg. of 3). Note: Requires P/N: 957099.901 for use with Q5000 SA.
Hangdown wires suspend down from the TGA Furnace Balance Mechanism and catch a sample pan's stirrup and lift the pan from the Autosampler and into the furnace. The hangdown wires come in a variety of materials and kit sizes.
Keep your balance free of contamination, and samples contained, with these Ohaus weighing dishes.
Replacement ICTAC Certified Curie Point Reference material 153 degrees Celcius