Test
Pure carbon support films with no Formvar backing. This new product has an even thinner carbon film which is mounted on a Lacey carbon film. The carbon support layer lying over the holes is less than 3nm in thickness and is the thinnest support film available. It is particularly useful for high resolution microscopy of low contrast particles and is also ideal for use with the Energy Filtering TEM.
Made from 0.004" tantalum foil. Replaceable tantalum apertures for some microscopes (Amray and Philips). They improve the performance of the electron gun.
Made from 0.004" tantalum foil. Replaceable tantalum apertures for some microscopes (Amray and Philips). They improve the performance of the electron gun.
Made from 0.004" tantalum foil. Replaceable tantalum apertures for some microscopes (Amray and Philips). They improve the performance of the electron gun.
Made from 0.004" tantalum foil. Replaceable tantalum apertures for some microscopes (Amray and Philips). They improve the performance of the electron gun.
Use on the EMS Tissue Chopper, EMS #93100 and EMS#93102.
Veco Grids offer superior handling characteristics. Plus, with a 0.8 mil thickness, Veco Grids are the most rigid grids available. 3.05 mm diameter and 0.8 mil thickness.
Grid: Nickel
Pitch: 167 µm
Hole: 117 µm
Bar: 50 µm
Veco Grids offer superior handling characteristics. Plus, with a 0.8 mil thickness, Veco Grids are the most rigid grids available. 3.05 mm diameter.
Grid: Nickel
Pitch: 333 µm
Hole: 283 µm
Bar: 50 µm
Veco Grids offer superior handling characteristics. Plus, with a 0.8 mil thickness, Veco Grids are the most rigid grids available. 3.05 mm diameter.
Grid: Nickel
Pitch: 125 µm
Hole: 85 µm
Bar: 40 µm
Gilder grids are a reliable support specimen grid for transmission electron microscopy. They feature a well-defined grid bars, maximum open area, and a matt/shiny side. Each grid is individually inspected.
Material: Copper
Pitch: 250 µm
Hole: 185 µm
Bar: 65 µm
Gilder grids are a reliable support specimen grid for transmission electron microscopy. They feature a well-defined grid bars, maximum open area, and a matt/shiny side. Each grid is individually inspected.
Material: Nickel
Pitch: 83 µm
Hole: 48 µm
Bar: 35 µm
EMBRA electroformed grids combine a high open area with a rigid construction which allows for relatively easy handling. 3.05 mm diameter, 50 micron thick for oval hole grids.
I.D.: 2 x 1 mm
Material: Stainless
Gilder grids are a reliable support specimen grid for transmission electron microscopy. They feature a well-defined grid bars, maximum open area, and a matt/shiny side. Each grid is individually inspected.
Material: Copper
Pitch: 83 µm
Hole: 48 µm
Bar: 35 µm
Immunogold reagent kit. Ultra-Small Starter Kit consists of 100 ulUltra-small Conjugate, 10ml BSA-c, 2x2.5ml R-Gent SE-LM and a sample pack R-Gent SE-EM
Biotinylated albumin conjugates contain equimolar amounts of conjugated protein.
Particle size: UltraSmall