Test
Centre Tube 2mm ID (EMT Torch); Centre tube intended for samples containing high dissolved solids.; Supplied as standard on all Duo iCAP instruments and can only be used; with the centre tube holder for the EMT torch.
Centre Tube Ceramic 2mm ID (EMT Torch); Centre tube intended for the analysis of samples containing HF acid.; Can only be used with the centre tube holder for the EMT torch.
NC1298600 EMT 1.0 MM CENTER TUBE
This module kit includes: Inner Chamber for External Ryton/Type II Spray Chamber, Qty. 1 (N0582258) Outer Axial Spray Chamber, Qty. 1 (N0775296) 1-Slot Quartz Torch, Qty. 1 (N0770338) GemTip Cross-Flow II Nebulizer, Qty. 1 (N0770546) 2.0 mm I.D. Alumina Injector (N0775177) Quick-Change Torch Module Mounting Block, Qty. 1 (N0770600) Scott Spray Chamber External Drain Kit, Qty. 1 (N0770613)
In general, the ceramic outer tube has a much longer lifetime, greatly reducing interruptions and downtime due to torch failure. The replaceable outer tube is more economical to replace than having to change the complex quartz assembly of the standard Optima torch. Furthermore, when analyzing difficult sample types, the quartz outer tube can devitrify in a few hours of operation, while the optional ceramic outer tube can last years under the same conditions. The ceramic outer tube is of particular benefit for: The analysis of wear metals in engine oils, where quartz outer tubes often suffer from short lifetime. Si determinations, where quartz outer tubes often produce high background signals. Fusion samples or samples with high levels of dissolved solids which cause quartz tubes to devitrify.
This kit includes: O-ring for Dual View Radial Purge Tube, 24.99 mm I.D. (09921036) O-Ring 36.09 mm I.D. (09921058) O-Ring for Dual View Axial Purge Window, 26.57 mm I.D. (09921062) Axial Purge Extension Window (09992731) Radial Purge Extension Window, Short Tube (N0690672)
This kit includes: 3-Slot Hybrid XLT Torch, Qty. 2 (N0790249) 1.2 mm I.D. Alumina Injector, Qty. 2 (N0791181) Baffled Cyclonic Spray Chamber, Qty. 1 (N0791352) Low-Flow GemCone Nebulizer, Qty. 1 (N0770358) Injector Adapter Kit, Qty. 1 (N0790141)
Features and Benefits include: An alumina intermediate tube which resists wear and is tolerant to high temperatures Demountable outer tube With the D-Torch, you need only replace the outer tube Interchangeable quartz and ceramic outer tubes Interchangeable injectors choose the optimum injector for your application. Select from quartz for aqueous solutions, narrow bore for organics, wide bore for high dissolved solids or ceramic for HF O-ring free torch body for simplified maintenance and improved reliability
This kit includes: GemCone Low-Flow Nebulizer (N0770358) Polyethylene Tubing for Nebulizer, 10 ft (09908265) Cyclonic Injector Adaptor Kit (N0790141) 3-Slot HybridXLT Organics Quartz Torch (N0790249) 1.2 mm I.D. Alumina Injector (N0791182) Glass Baffled Cyclonic Spray Chamber (N0791352) Adjustable Torch Body Assembly (N0810128)
The D-Torch is a revolutionary new demountable torch design with interchangeable outer tubes. Featuring a torch body with fixed alumina intermediate tube for greater robustness, in addition to a demountable outer tube and injector, the D-Torch significantly reduces torch replacement costs for the analysis of challenging sample matrices. The ceramic outer tube is of particular benefit for ICP applications where a quartz outer tube will suffer from a short lifetime. High TDS applications cause quartz to rapidly devitrify and organic solvents can cause quartz to fracture, whereas the ceramic outer tube will last years under the same conditions. The ceramic outer tube is of particular benefit for: The analysis of wear metals in engine oils, where quartz outer tubes often suffer from short lifetime. Si determinations, where quartz outer tubes often produce high background signals. Fusion samples or samples with high levels of dissolved solids which cause quartz tubes to devitrify.
Silver screen
NC1532448 ICAP 7400 PERISTALTIC PUMP
The Baffled Cyclonic Spray Chamber features a central transfer tube which acts as a secondary particle separator, helping to separate larger aerosol particles from the sample. This reduces solvent load in the plasma without compromising detection limits.
In general, the ceramic outer tube has a much longer lifetime, greatly reducing interruptions and downtime due to torch failure. The replaceable outer tube is more economical to replace than having to change the complex quartz assembly of the standard Optima torch. Furthermore, when analyzing difficult sample types, the quartz outer tube can devitrify in a few hours of operation, while the optional ceramic outer tube can last years under the same conditions. The ceramic outer tube is of particular benefit for: The analysis of wear metals in engine oils, where quartz outer tubes often suffer from short lifetime. Si determinations, where quartz outer tubes often produce high background signals. Fusion samples or samples with high levels of dissolved solids which cause quartz tubes to devitrify.
This Outer Tube is included in the D-Torch Complete Assembly with Quartz Outer Tube for Avio 200 (N0790442) and the D-Torch Complete Assembly with Quartz Outer Tube for Avio 500 (N0810861). Features and Benefits of the D-Torch include: Analysis of high-matrix solutions (i.e. fusion samples, samples with high-dissolved solids, samples with high-acid content) which can cause early devitrification or sample deposition when using quartz Demountable outer tube With the D-Torch, you need only replace the outer tube Interchangeable quartz and ceramic outer tubes (N0791303, N0811912) Interchangeable injectors choose the optimum injector for your application. Select from quartz for aqueous solutions, narrow bore for organics, wide bore for high dissolved solids or ceramic for HF