Gas Purifiers and Traps

Gas Purifiers and Traps
- (2)
- (2)
- (2)
- (2)
- (2)
- (2)
- (1)
- (5)
- (1)
- (2)
- (2)
- (2)
- (1)
- (3)
- (1)
- (1)
- (1)
- (1)
- (6)
- (1)
- (2)
- (2)
- (2)
- (2)
- (1)
- (1)
- (7)
- (1)
- (1)
- (2)
- (1)
- (2)
- (1)
- (4)
- (2)
- (2)
- (1)
- (1)
- (1)
- (6)
- (4)
- (5)
- (1)
- (2)
- (3)
- (1)
- (4)
- (4)
- (4)
- (4)
- (6)
- (5)
- (1)
- (1)
- (3)
- (1)
- (1)
- (1)
- (1)
- (1)
Filtered Search Results

Restek™ VICI™ Mat/Sen™ Gas-Specific Purifier Modules
Supplier Diversity Partner
Small and/or diverse supplier based on Federal laws and SBA requirements.
Learn More

Small and/or diverse supplier based on Federal laws and SBA requirements.
Learn More
Replaces separate oxygen, moisture, and hydrocarbon traps with one multiple-bed purifier, specific for purifying helium, hydrogen, nitrogen, or air
Flow Rate | 500 mL/min. |
---|---|
Length (Metric) | 52.3 cm |
Diameter (Metric) Outer | 3.8 cm |
Diameter (English) Outer | 1.5 in. |
Length (English) | 21 in. |
Material | Stainless Steel |
For Use With (Application) | Reduce gas impurities from ppm to low ppb levels, prepurged with the specified gas to shorten downtime |
Pressure | 1000 psi |
MilliporeSigma™ Supelco™ Supelcarb™ HC Hydrocarbon Trap
The best trap available for removing hydrocarbons and other organics from carrier, fuel, air, and other gas streams
Type | Hydrocarbon Trap |
---|---|
For Use With (Application) | Removing Hydrocarbons and Other Organics From Carrier, Fuel, Air, and Other Gas Streams |
Product Line | Supelcarb™ |
Restek™ Super-Clean™ Gas Filters
Supplier Diversity Partner
Small and/or diverse supplier based on Federal laws and SBA requirements.
Learn More

Small and/or diverse supplier based on Federal laws and SBA requirements.
Learn More
Gas filter cartridges with a high-purity output to ensure 99.9% pure gas for laboratories
Flow Rate | 7 L/min. |
---|---|
Length (Metric) | 27 cm |
Diameter (Metric) Outer | 4.4 cm |
Housing Material | Glass, Polycarbonate |
Diameter (English) Outer | 1.75 in. |
Length (English) | 10.62 in. |
Pressure | 159 psi |
Restek™ VICI met/sen Gas-Specific Purifier Modules
Supplier Diversity Partner
Small and/or diverse supplier based on Federal laws and SBA requirements.
Learn More

Small and/or diverse supplier based on Federal laws and SBA requirements.
Learn More
Replace separate oxygen, moisture, and hydrocarbon traps with one multiple-bed purifier, specific for purifying helium, hydrogen, nitrogen, or air.
Restek™ Super-Clean Gas Trapping System for LC/MS
Supplier Diversity Partner
Small and/or diverse supplier based on Federal laws and SBA requirements.
Learn More

Small and/or diverse supplier based on Federal laws and SBA requirements.
Learn More
Quick-change cartridge system removing hydrocarbons efficiently from nitrogen
For Use With (Equipment) | Super-Clean Gas Trapping System |
---|
MilliporeSigma™ Supelco™ Molecular Sieve 5A Moisture Traps
Efficiently remove moisture and heavy hydrocarbons from compressed air, electrolytically produced hydrogen, house nitrogen, or other gases with high moisture or hydrocarbon content
MilliporeSigma™ Supelco™ Supelpure™-O Oxygen/Moisture Trap
Oxygen-removing catalysts that can reduce oxygen to less than 2 ppb when the level in the incoming gas does not exceed 10 ppm
Type | Oxygen/Moisture Trap |
---|---|
For Use With (Application) | Removing Oxygen and Water Vapor From Incoming Gas |
Product Line | Supelpure™ |
Oxiclear™ Disposable Oxygen/Moisture Trap, Sold by MilliporeSigma™ Supelco™
Reduces oxygen to less than 1 ppm when the incoming level is below 10 ppm.
Type | Oxygen/Moisture Trap |
---|---|
Length (Metric) | 19 cm |
Diameter (Metric) Outer | 48 mm |
Diameter (English) Outer | 1.875 in. |
Length (English) | 7.5 in. |
For Use With (Application) | Reduces Oxygen, Removes Moisture and Organic Contaminants |
Product Line | Oxiclear™ |
Restek™ Indicating Moisture Trap
Supplier Diversity Partner
Small and/or diverse supplier based on Federal laws and SBA requirements.
Learn More

Small and/or diverse supplier based on Federal laws and SBA requirements.
Learn More
Restek™ Indicating Oxygen Traps
Supplier Diversity Partner
Small and/or diverse supplier based on Federal laws and SBA requirements.
Learn More

Small and/or diverse supplier based on Federal laws and SBA requirements.
Learn More
Prepurged for fast stabilization time
Includes | Vespel™ sealing rings |
---|---|
Gases Measured | Oxygen |
Type | Indicating Oxygen Trap |
Length (Metric) | 25.4 cm |
Efficiency | 0.1ppm |
Diameter (Metric) Outer | 3.2 cm |
Housing Material | Polycarbonate |
Diameter (English) Outer | 1.25 in. |
Length (English) | 10 in. |
Material | Glass |
Pressure | 100 psi |
Color Indicator | Yes |
Restek™ Filter and Baseplate Kits
Supplier Diversity Partner
Small and/or diverse supplier based on Federal laws and SBA requirements.
Learn More

Small and/or diverse supplier based on Federal laws and SBA requirements.
Learn More
Single-position mounting baseplate with 0.125 in. inlet/outlet fittings (06-711-828)
Style | Filter and Baseplate Kit |
---|
Restek™ Baseplates
Supplier Diversity Partner
Small and/or diverse supplier based on Federal laws and SBA requirements.
Learn More

Small and/or diverse supplier based on Federal laws and SBA requirements.
Learn More
Base plates fit all stand alone Super Clean gas filters offered.
Height (Metric) | 4.8 cm |
---|---|
Type | Filter Base Plate |
Width (English) | 4 in. |
For Use With (Equipment) | Super-Clean™ gas filter |
Connection Type | 0.25 in. Fitting |
Material | Brass |
Width (Metric) | 10.2 cm |
Height (English) | 1.87 in. |
Trajan Scientific and Medical Gas Filter - Carrier Gas
Supplier Diversity Partner
Small and/or diverse supplier based on Federal laws and SBA requirements.
Learn More

Small and/or diverse supplier based on Federal laws and SBA requirements.
Learn More
Prevent contaminants in gases from significantly impacting the quality of results. Oxygen, hydrocarbons and moisture can lead to problems such as noisy baselines, moisture entering the GC column, excessive bleed and septa degradation.
Economy Moisture-Removing Trap, 400 cc, MilliporeSigma™ Supelco™
The clear polycarbonate tubes contains a mixture of Molecular Sieve 13X and Molecular Sieve 4A with indicating capability. Because room air may permeate through the polycarbonate tube, this trap should not be used with carrier gas streams.
MilliporeSigma™ Supelco™ Molecular Sieve 5A Moisture Trap, S-Trap
Efficiently removes moisture and heavy hydrocarbons from compressed air, electrolytically produced hydrogen, house nitrogen, or other gases with high moisture or hydrocarbon content