Choose the brand aligned with your industry so we can best serve your needs.
NG-Test CARBA 5 is the only rapid, multiplex, phenotypic test capable of detecting KPC, OXA-48-like, VIM, IMP, and NDM carbapenemases produced by Enterobacterales and P. aeruginosa.
Licensed Cartridge Pack 0.05 EU/ML sensitivity The disposable cartridge contains four channels - two channels with CSE and LAL, which serve as the positive control channels, and two channels with LAL for testing of samples. To perform the test, add 25 ul of sample into all four sample reservoirs. The reader's internal pump moves the samples to the first reagent station for mixing. The pump then moves the samples to the second station for mixing, and lastly into the optical cells of the cartridge to be read kinetically.
10-TEST 1.2ML 12/CS ..
AMPISCREEN 800 PG KIT ..
The disposable cartridge contains four channels - two channels with CSE and LaL, which serve as the positive control channels, and two channels with LaL for testing of samples. To perform the test, add 25 ul of sample into all four sample reservoirs. The reader's internal pump moves the samples to the first reagent station for mixing. The pump then moves the samples to the second station for mixing, and lastly into the optical cells of the cartridge to be read kinetically. Sensitivity EU/ml 0.1. 10 single packs of cartridges.
MALDI-TOF BAC TEST STD 5TUBES ..
Cartridge; Endosafe PTS; Charles River Endosafe; For endotoxin determination using the PTS platform; Sensitivity 0.05 EU/mL
Stains cat scratch fever, H. pylori, l. pneumophila, and spirochetes. Kit includes 2% Silver Nitrate Acidulated, 0.5% Silver Nitrate Acidulated, 4% Gelatin Acidulated, 0.1% Hydroquinone Acidulated, and Spirochete Sensitizer Solution.
CHARIVR ENDOTOXIN 5/PK ..
10 single packs of cartridges All of our rapid testing instruments utilize our FDA-licensed cartridges for batch release testing, as well as a variety of non-regulated cartridges for simple, 15-minute testing. The cartridges are pre-loaded with all of the reagents required to perform an LAL test, eliminating preparation of multiple reagents and reducing the opportunity for technician error. Since there is no need to create a standard curve, create a positive product control and reconstitute LAL, there is no need for a negative control by the user. However, it is recommended that when performing sample dilutions, the diluent be tested for endotoxin prior to use.
E. coli O103 Latex Agglutination Test (LAT) Kit, (50T)
E. coli O26 Latex Agglutination Test (LAT) Kit, (50T)
NC0454805 E COLI O145
Accutest Uriscreen™ is a rapid screening test which combines the detection of both bacteriuria and pyuria (the presence of somatic cells in urine), by detecting catalase activity (an enzyme present in many eukaryotic cells). Accutest Uriscreen™ provides physicians’ offices, clinical laboratories and outpatient sites with a rapid and accurate screening method for urinary tract infections. Accutest Uriscreen’s negative predictive value (NPV) of 95%, is higher than the NPV of the urine dipstick. Accutest Uriscreen™ is a cost-effective, screening procedure, which can be used to complement conventional culture methods.
NC0947534 MICROCYSTIN-LR CHECK SAMPLE