HPLC Columns and Cartridges
HPLC Columns and Cartridges
Filtered Search Results
Thermo Scientific™ Hypersil GOLD™ C18 Selectivity HPLC Columns
Use these endcapped, ultrapure, silica-based columns to generate exceptional peak shape and resolution for HPLC and LC/MS analyses using generic gradients
Thermo Scientific™ Acclaim™ PepMap™ 100 C18 HPLC Columns
Use for high-resolution tryptic, natural, and synthetic peptide analyses. Its high loading capacity is exceptional for low abundant peptides in complex proteomic samples.
Pore Size | 100 Å |
---|---|
Stationary Phase | C18 |
Phase | Reversed Phase |
USP Type | L1 |
Thermo Scientific™ Syncronis™ C18 Columns
Use for hydrophobic interaction reversed-phase separations.
Pore Size | 100 Å |
---|---|
Carbon Load | 16% |
Stationary Phase | C18 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
pH | 2 to 9 |
Surface Area | 320 m²/g |
USP Type | L1 |
Thermo Scientific™ Acclaim™ 120 C18 Columns
Use these high-efficiency reversed phase C18 columns for maximum resolution in a wide variety of applications.
Pore Size | 120 Å |
---|---|
Carbon Load | 18% |
Stationary Phase | C18 |
Temperature | 60°C |
Endcapped | Yes |
Column Type | Reversed Phase |
pH | 2 to 8 |
Surface Area | 300 m²/g |
USP Type | L1 |
Hamilton™ PRP™-X300 Ion Exclusion HPLC Columns
Polymeric column packing for the separation of alcohols and organic acids
Pore Size | 100 Å |
---|---|
Stationary Phase | PRP-X300 |
Temperature | 5°C to 60°C |
Phase | Ion Exchange |
Column Type | Ion Exchange |
Material | Stainless Steel |
Max. Pressure | 5000 psi (345 bar) |
Column Format | Analytical Column |
Particle Size | 7 μm |
Type | Column |
Packing Material | PSDVB/Sulfonic Acid |
Mobile Phase Compatibility | pH 1 to 13, 0 to 100% aqueous, organic modifier |
Diameter (Metric) | 4.1 mm |
pH | 1 to 13 |
USP Type | L17 |
Hamilton™ PRP™-X200 Cation Exchange Columns
Analyze inorganic and organic cations using conductivity or UV detection. Separate mono or divalent cations depending on mobile phase conditions from 20 ppb to 200 ppm.
Pore Size | 100 Å |
---|---|
Stationary Phase | PRP-X200 |
Temperature | 5°C to 60°C |
Phase | Ion Exchange |
For Use With | Analyzing Inorganic and Organic Cations Using Conductivity or UV Detection |
Column Type | Ion Exchange |
Material | Stainless Steel |
Max. Pressure | 5000 psi (345 bar) |
Column Format | Analytical Column |
Particle Size | 10 μm |
Flow Rate | 2 mL/min |
Type | Column |
Packing Material | PSDVB/Sulfonic Acid |
Mobile Phase Compatibility | pH 1 to 13, 0 to 100% aqueous, organic modifier |
Diameter (Metric) | 4.1 mm |
pH | 1 to 13 |
USP Type | L22 |
Thermo Scientific™ Hypersil GOLD™ aQ C18 Polar Endcapped HPLC Columns
Retain and resolve polar analytes with highly aqueous mobile phases.
Pore Size | 175 Å |
---|---|
Carbon Load | 12% |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Polar |
Column Type | Reversed Phase |
pH | 2 to 9 |
Surface Area | 220 m²/g |
USP Type | L1 |
Thermo Scientific™ Hypercarb™ Porous Graphitic Carbon HPLC Columns
Use for enhanced retention of polar compounds and separation of structurally related analytes with stability at pH extremes and high temperature.
MilliporeSigma™ Supelco™ Ace Large Chromatography Column, 600 mm
Suitable for ion-exchange or activated-carbon work. Order column adapters separately.
Column Type | Chromatography |
---|---|
Material | Borosilicate Glass |
Product Line | Ace |
MilliporeSigma™ Supelco™ Kromasil C18 HPLC Column, 100 Å, 5 μm Particle Size
For small molecules and peptides.
Pore Size | 100 Å |
---|---|
Particle Size | 5 μm |
Stationary Phase | C18 (octadecyl) |
Phase | Reversed Phase |
Matrix | C18 (octadecyl) Phase |
Product Line | Kromasil |
Cytiva HiScale™ Columns Packed with Superdex™ Increase or Superose™ Increase Resins
Similar to the new-generation Superdex™ Increase and Superose™ Increase Size Exclusion Chromatography (SEC) Columns, but for use with purifying larger volumes of up to 8.5 mL
Type | Column |
---|---|
Content And Storage | Store at 4°C to 30°C, 20% Ethanol |
For Use With | Size Exclusion Chromatography (SEC) |
Quantity | 1 Ea. |
Max. Pressure | 2 MPa |
Thermo Scientific™ Hypersil™ MOS C8 LC Column, 5μm
Reliably analyze moderately hydrophobic analytes such as small peptides and proteins, pharmaceuticals, steroids and environmental samples.
Pore Size | 120 Å |
---|---|
Particle Size | 5 μm |
Carbon Load | 6.5% |
Stationary Phase | C8 |
Phase | Reversed Phase |
Column Type | Reversed Phase |
pH | 2 to 8 |
Surface Area | 170 m²/g |
USP Type | L7 |
Column Format | Analytical Column |
Restek™ Ultra HPLC Columns with C18 Column Packing, 5um Particle Size
Supplier Diversity Partner
Small and/or diverse supplier based on Federal laws and SBA requirements.
Learn More
Small and/or diverse supplier based on Federal laws and SBA requirements.
Learn More
Similar in pore size to Pinnacle II™ columns, but with greater retention
Pore Size | 100 Å |
---|---|
Particle Size | 5 μm |
Ligand Type | Monomeric C18 |
Carbon Load | 20% |
Stationary Phase | C18 |
Temperature | 80°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
pH | 2.5 to 8 |
Particle Shape | Spherical |
USP Type | L1 |
Thermo Scientific™ DNAPac™ PA200 Oligonucleotide HPLC Columns
Enjoy strong anion exchange for high-resolution analysis and purification of synthetic oligonucleotides with Thermo Scientific™ DNAPac™ PA200 Oligonucleotide HPLC Columns.
Pore Size | Nonporous |
---|---|
Stationary Phase | Quaternary Ammonium |
Temperature | 85°C |
Phase | Ion Exchange |
Column Type | Ion Exchange |
Technique | Bio-LC |
Product Line | DNAPac |
Thermo Scientific™ ProPac™ WCX-10 HPLC Columns
Separate proteins and their variants using these weak cation-exchange columns with exceptionally high resolution.
Pore Size | Nonporous |
---|---|
Particle Size | 10 μm |
Stationary Phase | Carboxylate |
Temperature | 60°C |
Phase | Ion Exchange |
Column Type | Ion Exchange |
pH | 2 to 12 |
Product Line | ProPac |