IC Guard Columns and Cartridges
IC Guard Columns and Cartridges
MilliporeSigma™ Supelco™ Chromolith™ Guard Cartridge Holder
The Chromolith™ 5-2 guard cartridge holder bioinert is suitable to connect any Chromolith™ guard cartridge to an analytical Chromolith™ HPLC column.
Thermo Scientific AG14 GUARD COLUMN 4MM
IonPac AG14 Guard Column, Dimensions:4 x 50 mm, Maximum Operating Pressure: 27.6 MPa (4000 psi), Mobile Phase Compatibility: pH 2-11; 0-100% HPLC solvents,Bead Diameter ( micrometer): 9.0 micrometer, Pore Size: 100 angstrom, Crosslinking (%

Thermo Scientific Dionex™ CarboPac™ PA200 IC Columns for Dual EGC Mode
Type Guard Column | Length (Metric) 50 mm | Particle Size 5.5 µm | Diameter (Metric) 1.0 mm | Max. Pressure 4500 psi (at 0.063 mL/min.) | Temperature (Metric) 4°C to 60°C | For Use With (Application) Complex Carbohydrate Analysis in Dual EGC Mode | Column Construction PEEK Resin Composition 5.5 µm diameter ethylvinylbenzene/divinylbenzene substrate (55% cross-linked) agglomerated with 43 nm microbead quaternary amine functionalized latex (6% cross-linked). | For Use With (Equipment) Dionex CarboPac PA200, 1.0 x 250 mm Analytical Column

Thermo Scientific Dionex™ CarboPac™ PA20-Fast-4µm IC Column Microbore Guard
Type Microbore Guard | Flow Rate 0.25 mL/min. | pH 0 to 14 | Length (Metric) 30 mm | Particle Size 6 µm | Diameter (Metric) 2 mm | Max. Pressure 5000 psi (345 bar) | Temperature (Metric) 4°C to 60°C | For Use With (Application) Carbohydrate Analysis | Column Capacity 4.5 µeq | Column Construction PEEK | Column Chemistry Hydroxide | Mobile Phase Compatibility pH 0 to 14, 0 to 50% Acetonitrile, Methanol, or Acetone | Anion Exchange Capacity 4.5 µeq |Resin Composition 6 µm Diameter Substrate (Ethylvinylbenzene 55% Crosslinked with Divinylbenzene) Agglomerated with 130 nm MicroBead Difunctional Quaternary Ammonium Ion (5.2% Crosslinked) | For Use With (Equipment) Dionex CarboPac PA20-Fast-4 µm Microbore Analytical Column

Thermo Scientific GUARD COLUMN IONPAX AG9-HC
IonPac AG9-HC Guard Column (4 x 50 mm), Maximum Operating Pressure: 4000 psi, Mobile Phase Compatibility: pH 0-12; 0-100% HPLC solvents, Bead Diameter: 9.0 micrometer, Pore Size: 2000 angstrom, Crosslinking (%DVB): 55%, Functional Group: Al

THERMO SCI 3P AIG PARTS & ACCESSORIES DIONEX IONPAC AS28 4UM GUARD
NC1079332 DIONEX IONPAC AS28 4UM GUARD

Metrohm USA METROHM CAUTION GUARD COLUMN
The Metrosep C 4 Guard/4.0 contains the C-4 column material and is used to protect all Metrosep cation columns that have a substrate based on silica gel. Particles and contaminations are reliably retained, allowing the lifetime of the analytical separation column to be prolonged considerably. The economical price is an additional plus. The Metrosep C 4 Guard/4.0 also functions according to the "On Column Guard System" and is screwed directly onto the separation column with nearly no dead volume.

THERMO SCI 3P AIG PARTS & ACCESSORIES IPAC AG16-4UM 4X50MM GUARD COL
NC1728597 IPAC AG16-4UM 4X50MM GUARD COL

Metrohm USA A SUPP 16 GUARD 4.0
The Metrosep A Supp 16 is the high-capacity version of the Metrosep A Supp 15 and is also based on a surface-functionalized polystyrene-divinylbenzene copolymer. The functional groups are bonded covalently. The morphology of the anion exchanger results in unique selectivity. In addition, this column type is noteworthy for its high mechanical and chemical resilience. The column is well-suited to applications with a high ionic load but which require only relatively low resolution. Using the Metrosep A Supp 16 - 100/4.0 to determine bromate in water by means of the triiodide method (EPA 326, DIN EN ISO 11206) is another of its numerous applications.

THERMO SCI 3P AIG PARTS & ACCESSORIES IONPAC AG-11 50X4.0MM GUARD
NC0403752 IONPAC AG-11 50X4.0MM GUARD
