Test
A 4mm x 150mm ion chromatography column containing continuously regenerated divinylbenzene cation exchange resin for separating and analyzing monovalent and divalent cations with fast kinetics, high capacity and low baseline noise.
CR-ATC Continuously Regenerated Anion Trap Column
Ionpac ATC-HC AnionN Trap Column, 9 x 75mm, Packing Specification: Column: ATC-HC, Particle Diameter: 750micrometer, Substrate X-Linking: 8, Substrate Type: Microporous, Column Capacity mEq/column: 4.0, Functional Group: Quaternary Ammoni
IonPac CTC-1 Cation Trap Column
The OPTI-PAK™'s unique hardware design integrates a PEEK holder with an auto-adjusting stem which provides a fluid interface with any 10-32 standard injector port, and guarantees a zero-dead-volume connection despite variances in tube stop depth. A proprietary method of frit placement allows the packed stem to be positioned directly into the flow path, which eliminates all excess swept volume. Less swept volume translates to absolute minimum sample dilution and dispersion. The elegant, flexible design of OPTI-PAK™ makes it amenable to virtually any trapping application. Installing an OPTI-PAK™ into the outlet of a switching valve will facilitate the trapping, desalting, and pre-concentration of an analyte mixture. With OPTI-PAK™s versatility, a second trap can be added downstream in the loop of an injection valve and effectively perform a 2D separation.
NC2323749 DIONEX CR-ATC TRAP COLUMN
600 MM long anion trap column containing polymethacrylate based anion exchange resin in hydroxide form designed to remove trace chloride, sulfate, carbonate anions from eluent prior to entering IC separation column, thereby improving baseline stability & noise, has 4 MM internal diameter & is made of inert polyether ether ketone polymer, can be used with common IC eluents like sodium hydroxide & sodium carbonate solutions.
CR-CTC II Continuously Regenerated Cation Trap Column
NC0594493 ATC-3
NC0682826 CR-CTC 500 CONTINUOUSLY REGENR
Metal-Free Trap Column, Removes trace transition metal contaminants from high-pH eluents, For use with high-pressure IC systems up to 5000 psi, Medium hydrophobicity, Particle size 200 m, Stationary phase chelating resin
MFC-1 Metal-Free Column
Anion trap column with anion exchange resin for high pressure 600 psi ion chromatography systems enables continuous regeneration by water to remove anions from eluent and improve conductivity detection by eliminating background contaminants.
For use with: 5 mL AS-DV PolyVials. Material: Hydrophilic reversed phase resin.
NC0784550 IONPAC CP2H 9X24MM