Melting Point Instruments
Melting Point Instruments
Fisherbrand™ Digital Melting Point Apparatus
Rotating viewing head ensures each user can analyze samples clearly
BUCHI Calibration and Verification Standards for BUCHI Melting Point Instruments


Utilize the embedded firmware and software on your Melting Point apparatus to calibrate and verify your instrument at any time.
Mettler Toledo™ Sample Tubes for MP50 Melting Point Instrument
Replacement part for MP50 Melting Point Instrument.
BUCHI Capillaries for Melting Point Apparatus


For use with BUCHI Melting Point apparatus.
METTLER TOLEDO™ Melting Point System MP70
One Click™ melting point for higher throughput and advanced analyses
METTLER TOLEDO™ Melting Point System MP55
Simple and versatile One Click™ melting point determination
METTLER TOLEDO™ Melting Point System MP30
One Click™ melting point for simple analyses
BUCHI Melting and Boiling Point Instruments


Fast and accurate. BUCHI M-560/565 Melting Point Instruments have simple menus and programs that are easy to navigate on the intuitive LCD display, with either manual or automatic, real time video instrument.
BUCHI Mini Keyboard for M-560/M-565 Melting Point Instrument

Speed up data input for your system with this mini keyboard.
BUCHI Compaction Wire for M-560/M-565 Melting Point Instrument

Ensure consistent sample preparation with a compaction wire for your system.
Stuart™ SMP50 Automatic Digital Melting Point Apparatus
Ideal for pharmaceutical, raw material, and quality control applications.
Stuart™ Analog Melting Point Apparatus
Stuart™ Analog Melting Point Apparatus makes viewing easy with integral LED illumination and magnifying lens
Electrothermal Programmable Digital Melting Point Apparatus with Beginning/Ending Recording
Electrothermal Programmable Digital Melting Point Apparatus with Beginning/Ending Recording features rotating viewing head ensuring each user can analyze samples clearly
Stuart™ Digital Melting Point Apparatus, SMP10 Model; 1° resolution
Easily operated apparatus, designed for educational use.
Electrothermal Mel-Temp™ Digital Melting Point Apparatus
Accommodates three melting point capillaries of up to 2mm O.D
Techne™ Advanced Melting Point Apparatus
Features patented head up display
Humboldt Softening Point Apparatus

Apparatus, Softening Point; Humboldt; With beaker; Shouldered ring-and-ball; Consists of beaker with shelving, two std. balls, two rings, cover; Samples held within horizontal rings; Steel balls placed on top of samples
Vernier Vernier Melt Station


Accurately determine melting temperature of solid substances.
Vernier Vernier Melt Station Capillary Tubes


For use with Vernier Melt Station.
Chemglass Life Sciences Melting Point Tubes, Closed One End, .8mm-1.1mm O.D. x 0.25mm Wall, Vial of 100, 90mm Length

Melting Point Tubes, Closed One End, .8mm-1.1mm O.D. x 0.25mm Wall, Vial of 100, 90mm Length. Similar to CG-1840, but closed at one end. Tube is manufactured from borosilicate glass and packaged 100 tubes per vial. The Code -02 has a smaller I.D. to conform to U.S.P XXI requirements.

Cole-Parmer Stuart Analog Melting Point Apparatus, 120 VAC
Take melting point measurements of up to three samples at once for greater efficiency. Simple to operate, the instructions are printed directly on the unit. Place your sample in a capillary tube and insert it into the aluminum block. Manually set the heating rate between 1°C and 20°C per minute, up to a maximum of 250°C. Lowering the heating rate as you near the expected melting point temperature will increase the accuracy of the reading. Observe the sample through the magnifying lens until the melt occurs and read the melt temperature from the thermometer.
Apparatus is supplied with open-ended capillary tubes. One end should be sealed with a Bunsen burner; or purchase optional capillary tubes separately that are already sealed. Order the optional brass cooling plug to speed up cooling when multiple runs are needed.

Cole-Parmer Electrothermal Serial Printer
This printer is compatible with Electrothermal's digital melting point meters.

Cole-Parmer Stuart SMP10 Digital Melting Point Apparatus, 120 VAC
This melting point apparatus lets you select, measure and display the temperature digitally, ensuring accuracy and repeatability. Easily view the melt using the illuminated magnifying lens. The apparatus allows you to be more productive by testing multiple samples at the same time. Save time, too, by setting a plateau temperature for its initial warm-up. The model, SMP10 provides 300C maximum temperature with 1resolution. It operates at 120 VAC.

Stanford Research Systems Inc Printer, with cable and paper

Printer, with cable and paper for MPA100 OptiMelt Automated Melting Point System.

Stanford Research Systems Inc Melting Point Apparatus MPA160

DigiMelt is a modern, low cost, digital melting point apparatus designed specifically for the student lab. Students learn the visual detection capillary method of melting point determination without the frustration of trying to control the oven temperature. DigiMelt rapidly heats the oven to the programmed start temperature, then ramps at the specified rate. The student carefully observes the samples and records the melting points with a touch of a button.

Chemglass Life Sciences Melting Point Tubes, Closed One End, 1.5mm-1.8mm O.D. x 0.20mm Wall, Vial of 100, 90mm Length

Melting Point Tubes, Closed One End, 1.5mm-1.8mm O.D. x 0.20mm Wall, Vial of 100, 90mm Length. Similar to CG-1840, but closed at one end. Tube is manufactured from borosilicate glass and packaged 100 tubes per vial. The Code -02 has a smaller I.D. to conform to U.S.P XXI requirements.

- 1
- 2