Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - FID Only with Enhanced Probe
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
Width (English) | 9 in. |
---|---|
Response Time | Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane |
Detection Limits | 0.5 ppm of methane |
Width (Metric) | 22.9 cm |
Detector Type | Flame Ionization Detector (FID) |
Flow Rate | 1 L/min., nominal at sample probe inlet |
Components Measured | Most Organic and Inorganic Compounds |
Accuracy | ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm |
Battery Life | 10 hours at 0°C |
Voltage | 120 V |
Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
Height (English) | 11.5 in. |
Height (Metric) | 29.2 cm |
Warranty | One year from date of shipment |
Depth (English) | 4 in. |
Concentration | 0 to 30,000 ppm (methane) |
Battery Type | Lithium Ion |
Repeatability | ±2% at 500 ppm of methane |
Serial Interface | USB |
Computer Requirements | USB port, Windows XP operating system or higher |
Depth (Metric) | 10.2 cm |
Fuel | 99.99% H2 for FID |
Temperature Range (English) | 14°F to 113°F |
Frequency | 50/60 Hz |
Portable Operation Time | Minimum 10 hours |
Temperature Range (Metric) | -10°C to 45°C |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - Dual FID/PID with Enhanced Probe
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
Width (English) | 9 in. |
---|---|
Response Time | FID: Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane; PID: Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene |
Detection Limits | FID: 0.5 ppm of methane; PID: 0.5 ppm of isobutylene |
Width (Metric) | 22.9 cm |
Detector Type | Dual Configured with FID and PID |
Flow Rate | 1 L/min., nominal at sample probe inlet |
Components Measured | Most Organic and Inorganic Compounds |
Accuracy | FID Instrument - ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm; PID Instrument - ±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
Battery Life | 10 hours at 0°C |
Voltage | 120 V |
Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
Height (English) | 11.5 in. |
Height (Metric) | 29.2 cm |
Warranty | One year from date of shipment |
Depth (English) | 4 in. |
Concentration | FID: 0 to 30,000 ppm (methane); PID: 0 to 2000 ppm (isobutylene) |
Battery Type | Lithium Ion |
Repeatability | FID: ±2% at 500 ppm of methane; PID: ±1% at 100 ppm of isobutylene |
Serial Interface | USB |
Computer Requirements | USB port, Windows XP operating system or higher |
Depth (Metric) | 10.2 cm |
Fuel | 99.99% H2 for FID |
Temperature Range (English) | 14°F to 113°F |
Frequency | 50/60 Hz |
Portable Operation Time | Minimum 10 hours |
Temperature Range (Metric) | -10°C to 45°C |
Dräger™ accuro™ Bellows Pump: Hardside Kit
Ergonomic design allows easy measurement of more than 350 gases—including formaldehyde
Components Measured | Carbon Monoxide |
---|---|
Quantity | 10 |
PureAire Monitoring Systems Dual O2/CO2 Monitor
Supplier Diversity Partner
Small and/or diverse supplier based on Federal laws and SBA requirements.
Learn More
Small and/or diverse supplier based on Federal laws and SBA requirements.
Learn More
PureAire Monitoring Systems Dual O2/CO2 Monitor designed for continuous monitoring in confined spaces
Components Measured | Formaldehyde |
---|---|
Quantity | 10 |
Humidity Range | 3 to 15mg/L |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - FID Only with Sampling Probe
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
Width (English) | 9 in. |
---|---|
Response Time | Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane |
Detection Limits | 0.5 ppm of methane |
Width (Metric) | 22.9 cm |
Detector Type | Flame Ionization Detector (FID) |
Flow Rate | 1 L/min., nominal at sample probe inlet |
Components Measured | Most Organic and Inorganic Compounds |
Accuracy | ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm |
Battery Life | 10 hours at 0°C |
Voltage | 120 V |
Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
Height (English) | 11.5 in. |
Height (Metric) | 29.2 cm |
Warranty | One year from date of shipment |
Depth (English) | 4 in. |
Concentration | 0 to 30,000 ppm (methane) |
Battery Type | Lithium Ion |
Repeatability | ±2% at 500 ppm of methane |
Serial Interface | USB |
Computer Requirements | USB port, Windows XP operating system or higher |
Depth (Metric) | 10.2 cm |
Fuel | 99.99% H2 for FID |
Temperature Range (English) | 14°F to 113°F |
Frequency | 50/60 Hz |
Portable Operation Time | Minimum 10 hours |
Temperature Range (Metric) | -10°C to 45°C |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - Dual FID/PID (No Probes)
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
Width (English) | 9 in. |
---|---|
Response Time | FID: Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane; PID: Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene |
Detection Limits | FID: 0.5 ppm of methane; PID: 0.5 ppm of isobutylene |
Width (Metric) | 22.9 cm |
Detector Type | Dual Configured with FID and PID |
Flow Rate | 1 L/min., nominal at sample probe inlet |
Components Measured | Most Organic and Inorganic Compounds |
Accuracy | FID Instrument - ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm; PID Instrument - ±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
Battery Life | 10 hours at 0°C |
Voltage | 120 V |
Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
Height (English) | 11.5 in. |
Height (Metric) | 29.2 cm |
Warranty | One year from date of shipment |
Depth (English) | 4 in. |
Concentration | FID: 0 to 30,000 ppm (methane); PID: 0 to 2000 ppm (isobutylene) |
Battery Type | Lithium Ion |
Repeatability | FID: ±2% at 500 ppm of methane; PID: ±1% at 100 ppm of isobutylene |
Serial Interface | USB |
Computer Requirements | USB port, Windows XP operating system or higher |
Depth (Metric) | 10.2 cm |
Fuel | 99.99% H2 for FID |
Temperature Range (English) | 14°F to 113°F |
Frequency | 50/60 Hz |
Portable Operation Time | Minimum 10 hours |
Temperature Range (Metric) | -10°C to 45°C |
Labconco™ Inflow and Downflow Sensor Kit
Supplier Diversity Partner
Small and/or diverse supplier based on Federal laws and SBA requirements.
Learn More
Small and/or diverse supplier based on Federal laws and SBA requirements.
Learn More
Allows display of inflow and downflow velocities on the LCD information center on MyLogic™ Digital Display.
Mettler Toledo™ InLab™ 605-ISM Dissolved Oxygen Sensors
For use with the SevenExcellence™ bench meter and the SevenGo Pro™ portable instrument.
Labconco™ Oxygen Monitor, 0.1 to 100%
Supplier Diversity Partner
Small and/or diverse supplier based on Federal laws and SBA requirements.
Learn More
Small and/or diverse supplier based on Federal laws and SBA requirements.
Learn More
Measures percent of oxygen inside the glove box using a chemical-resistant electrochemical sensor
Includes | 10 ft. of interconnecting sensor cable, power cord for connection to the glove box's interior electrical receptacle and mounting bracket for hanging from Interior Shelves (5061600, sold separately) or Rear Interior Shelf Kit (5235000, sold separately) |
---|---|
Display Type | LCD |
Product Type | Oxygen Monitor |
Frequency | 50/60 Hz |
Supel™-Inert Multi-Layer Foil Gas Sampling Bags, Sold by MilliporeSigma™ Supelco™
Ideal for sampling low molecular weight compounds. Two outer layers of aluminum film provide a great barrier to gases permeating through the walls of the bag.
Description | Chemically Inert with Light/Moisture Protection |
---|---|
Port Detail | Thermogreen™ LB-2 Septa |
Resistant To | Chemicals |
No. per Pack | 10 |
Certifications/Compliance | NIOSH 6603, OSHA ID-172 (ID-210) |
For Use With (Application) | Sampling Low Molecular Weight Compounds Such as Carbon Monoxide (CO), Carbon Dioxide (CO2) and Permanent Gases. Also Suitable for Sampling Sulfur Compounds Such as Hydrogen Sulfide (H2S), Carbon Disulfide (CS2) and Mercaptans. |
Closure Type | Screw Cap Valve (SCV) |
Product Line | Supel™ |
Film Description | Multi-layer foil composed of two outer layers of aluminum film |
MilliporeSigma™ Supelco™ Supel™-Inert Multi-Layer Foil Gas Sampling Bag
Ideal for sampling low molecular weight compounds such as carbon monoxide (CO), carbon dioxide (CO2) and permanent gases
Includes | Push/Pull Lock Valve (PLV) |
---|---|
Quantity | 10/Pk. |
Material | Multi-layer Foil |
Product Line | Supel™ |
MilliporeSigma™ Supelco™ Tedlar™ Gas Sampling Bag for EPA TCLP Method
Tedlar™ is recommended in several US EPA methods for sampling VOCs and sulfur compounds.
MilliporeSigma™ Supelco™ Tedlar™ PLV Gas Sampling Bag with Thermogreen™ LB-2 Septa
Tedlar™ is recommended in several US EPA methods for sampling VOCs and sulfur compounds.
Includes | Push/Pull Lock Valve (PLV) |
---|---|
Material | PVDF Film |
Product Line | Tedlar |