Learn More
Thermo Scientific™ LightShift™ Chemiluminescent RNA EMSA Kit
Study RNA-protein interactions with this non-radioactive EMSA kit for gel shift assays.
Supplier: Thermo Scientific™ 20158
Description
Thermo Scientific™ LightShift Chemiluminescent RNA EMSA Kit provides a non-radioactive solution for studying RNA-protein interactions using an electrophoretic mobility-shift assay (EMSA).
The RNA EMSA Kit uses biotinylated RNA probes and a chemiluminescent substrate system to achieve fast and safe detection of RNA-protein complexes with sensitivity equivalent to traditional 32P-isotopic methods. The complete kit comes with all reagents required to set up and optimize protein-RNA binding conditions, a positive control for protein-RNA interactions and reagents for chemiluminescent detection of the nucleic acid interaction.Highlights:
Sensitive – chemiluminescent detection comparable to radioactive detection
Time-saving – develop X-ray films after 1- to 5-minute exposures, versus 16 hour exposures needed with radioactive systems
Flexible – compatible with RNA probes biotinylated by different methods
Easy to use – complete kit includes optimized reagents for binding reactions and RNA probe detection
Non-radioactive – eliminate waste concerns from radioactive RNA probes
Specifications
EMSA Assay | |
Chemiluminescence | |
Protein | |
100 reactions | |
LightShift Chemiluminescent RNA EMSA Kit | |
Enhanced Chemiluminescence, Membrane Blot, Gel Shift |
Sufficient For: 100 binding reactions and detection on 1000 cm2 of membrane (10 mini-gel blots)• 125 nM Biotinylated IRE RNA Control 35 μL (store at -20°C) • 10 μM Unlabeled IRE RNA Control, 25 μL (store at -20°C) • 2 mg/mL Cytosolic Liver Extract, 50 μL (store at -20°C) • 10 mg/mL tRNA, 100 μL (store at -20°C) • 10X REMSA Binding Buffer, 1 mL (store at -20°C) • 50% Glycerol, 500 μL (store at -20°C) • 2M KCl, 500 μL (store at -20°C) • 1M MgCl2, 500 μL (store at -20°C) • DTT, lyophilized (store at -20°C) • Nuclease-Free Water, 1.5 mL (store at -20°C) • 5X REMSA Loading Buffer, 1 mL (store at -20°C) • Stabilized Streptavidin-HRP, 1.5 mL (store at 4°C) • Luminol/Enhancer Solution, 80 mL (store at 4°C) • Stable Peroxide Solution, 80 mL (store at 4°C) • Nucleic Acid Detection |
|
Kit | |
myECL™ Imager, X-Ray Film | |
LightShift™ | |
Not Target-Specific |
Safety and Handling
Your input is important to us. Please complete this form to provide feedback related to the content on this product.
For Research Use Only. Not for use in diagnostic procedures.