The BioTek 405 LS washer has a well earned reputation as an economical plate washer that offers excellent performance and reliability. For In Vitro Diagnostic Use.

Specifications

Certifications/Compliance CE and TUV marked. RoHS compliant.
Bottles Optional (4 or 10 L)
Precision <3% CV: 300 μL/well (96-well washing); <4% CV: 80 μL/well (384-well washing)
Dispense Volume 25 to 3000 μL/well
Plate Type 96- and 384-well; Low profile and standard height; Solid and filter bottom (filter pore sizes 0.45 to 1.2 μm) plates
View More Specs

Products 14
Catalog Number Mfr. No. Model Includes Price Quantity & Availability  
Catalog Number Mfr. No. Model Includes Price Quantity & Availability  
BT405LSRSI
View Documents
Agilent BioTek
405LSRSI
405LSR 96-well microplate washing N/A N/A
This product is not available for sale online. Please contact Customer Service at 1-800-766-7000 or send email to cs.webemail@thermofisher.com to discuss your specific assay requirements.
BT405LSUSI
View Documents
Agilent BioTek
405LSUSI
405LSU 96-/384-well microplate washing N/A N/A
This product is not available for sale online. Please contact Customer Service at 1-800-766-7000 or send email to cs.webemail@thermofisher.com to discuss your specific assay requirements.
BT405LSHTSI
View Documents
Agilent BioTek
405LSHTSI
405LSHT Ultrasonic Advantage; Faster 384-well microplate washing N/A N/A
This product is not available for sale online. Please contact Customer Service at 1-800-766-7000 or send email to cs.webemail@thermofisher.com to discuss your specific assay requirements.
BT405LSRSSI
View Documents
Agilent BioTek
405LSRSSI
405LSRS Ultrasonic Advantage; 96-well microplate washing N/A N/A
This product is not available for sale online. Please contact Customer Service at 1-800-766-7000 or send email to cs.webemail@thermofisher.com to discuss your specific assay requirements.
BT405LSUSSI
View Documents
Agilent BioTek
405LSUSSI
405LSUS Ultrasonic Advantage; 96-/384-well microplate washing N/A N/A
This product is not available for sale online. Please contact Customer Service at 1-800-766-7000 or send email to cs.webemail@thermofisher.com to discuss your specific assay requirements.
BT405LSRVSI
View Documents
Agilent BioTek
405LSRVSI
405LSRV Automated Internal 4-Buffer Switching; 96-well microplate washing N/A N/A
This product is not available for sale online. Please contact Customer Service at 1-800-766-7000 or send email to cs.webemail@thermofisher.com to discuss your specific assay requirements.
BT405LSUVSI
View Documents
Agilent BioTek
405LSUVSI
405LSUV Automated Internal 4-Buffer Switching; 96-/384-well microplate washing N/A N/A
This product is not available for sale online. Please contact Customer Service at 1-800-766-7000 or send email to cs.webemail@thermofisher.com to discuss your specific assay requirements.
BT405LUSQSI
View Documents
Agilent BioTek
405LSUSQSI
405LSUSQ Ultrasonic Advantage; 96-/384-well microplate washing; Verify Technology N/A N/A
This product is not available for sale online. Please contact Customer Service at 1-800-766-7000 or send email to cs.webemail@thermofisher.com to discuss your specific assay requirements.
BT405LRSQSI
GREENER_CHOICE
View Documents
Agilent BioTek
405LSRSQSI
405LSRSQ Ultrasonic Advantage; 96-well microplate washing; Verify Technology N/A N/A
This product is not available for sale online. Please contact Customer Service at 1-800-766-7000 or send email to cs.webemail@thermofisher.com to discuss your specific assay requirements.
BT405LHTVSI
GREENER_CHOICE
View Documents
Agilent BioTek
405LSHTVSI
405LSHTV Automated Internal 4-Buffer Switching; Faster 384-well microplate washing N/A N/A
This product is not available for sale online. Please contact Customer Service at 1-800-766-7000 or send email to cs.webemail@thermofisher.com to discuss your specific assay requirements.
BT405LRVSSI
View Documents
Agilent BioTek
405LSRVSSI
405LSRVS Automated Internal 4-Buffer Switching; Ultrasonic Advantage; 96-well microplate washing N/A N/A
This product is not available for sale online. Please contact Customer Service at 1-800-766-7000 or send email to cs.webemail@thermofisher.com to discuss your specific assay requirements.
BT405LUVSSI
GREENER_CHOICE
View Documents
Agilent BioTek
405LSUVSSI
405LSUVS Automated Internal 4-Buffer Switching; Ultrasonic Advantage; 96-/384-well microplate washing N/A N/A
This product is not available for sale online. Please contact Customer Service at 1-800-766-7000 or send email to cs.webemail@thermofisher.com to discuss your specific assay requirements.
BT405LRVQSI
GREENER_CHOICE
View Documents
Agilent BioTek
405LSRVSQSI
405LSRVSQ Automated Internal 4-Buffer Switching; Ultrasonic Advantage; 96-well microplate washing; Verify Technology N/A N/A
This product is not available for sale online. Please contact Customer Service at 1-800-766-7000 or send email to cs.webemail@thermofisher.com to discuss your specific assay requirements.
BT405LUVQSI
GREENER_CHOICE
View Documents
Agilent BioTek
405LSUVSQSI
405LSUVSQ Automated Internal 4-Buffer Switching; Ultrasonic Advantage; 96-/384-well microplate washing; Verify Technology N/A N/A
This product is not available for sale online. Please contact Customer Service at 1-800-766-7000 or send email to cs.webemail@thermofisher.com to discuss your specific assay requirements.
Description

Description

The BioTek 405 LS washer has a well earned reputation as an economical plate washer that offers excellent performance and reliability. Washing protocols range from gentle cell washing to vigorous ELISA workflows. The 405 LS has a simple user interface for creation and execution of wash, dispense, aspirate, and maintenance protocols within the extensive onboard software

For use under computer control, Agilent BioTek LHC software used with the 405 LS is available in standard and 21 CFR Part 11 compliant versions. The optional Agilent BioTek BioStack is available for walk-away automation of up to 50 microplates.

 

Must be purchased together with required dispense/waste system accessory for use. Please contact your Fisher Sales Representative for more information.

Specifications

Specifications

CE and TUV marked. RoHS compliant.
<3% CV: 300 μL/well (96-well washing); <4% CV: 80 μL/well (384-well washing)
96- and 384-well; Low profile and standard height; Solid and filter bottom (filter pore sizes 0.45 to 1.2 μm) plates
96-wells: 300 μL/well, 3 cycles: <30 s; 384-wells: 100 μL/well, 3 cycles: <80 s; 384-wells: 400 μL/well, 1 cycle: <20 s
Microplate Washer
1 to 250
10 to 85%, noncondensing
1 μL
35.6 cm
25.4 cm
43.2 cm
100/240 V
Optional (4 or 10 L)
25 to 3000 μL/well
<2 μL/well (96- & 384-well plates); 96-tube manifold for 96 wells; 192-tube for 384 wells
Programmable in minutes and seconds, up to 60 min.
With internal buffer switching - 16.5 kg; Without - 13.5 kg
High to Low Flow; Optimized rates for cell assays
50/60 Hz
14 in.
10 in.
17 in.
With internal buffer switching - 36 lb.; Without - 30 lb.