Real Time PCR Reagents and Kits
Real Time PCR Reagents and Kits
Products designed for use during real-time (quantitative) PCR procedures. Includes master mixes, DNA polymerases, reverse transcriptases, size standards, kits, and reagents.
Reverse transcription polymerase chain reaction (RT-PCR) is a laboratory technique that combines the reverse transcription of RNA into DNA and the subsequent amplification of the DNA using PCR.
In RT-PCR, a reverse transcriptase enzyme converts an RNA template to its complementary DNA (cDNA). The cDNA then becomes the template for PCR amplification.
A typical RT-PCR kit includes the main components needed for the assay:
- Buffer
- Primers – a combination of deoxynucleotide triphosphates (dNTPs) of the four bases of adenine (dATP), cytosine (dCTP), guanine (dGTP), and thymine (dTTP)
- Reverse transcriptase reagent
The combination of RT-PCR and qPCR techniques (sometimes labelled RT-qPCR) is often used in research and clinical labs to analyze gene expression and quantify viral RNA. Since this method uses fluorescence to track the amplification reaction, these kits may also include:
- Fluorogenic primers or labeled fluorogenic probes
- Fluorescent dye
Reagents for cDNA PCR can be purchased separately or as cDNA synthesis kits.
RT-PCR is commonly used for RNA detection, molecular cloning, and gene sequencing. RT-qPCR is used for gene expression analysis, RNAi or microarray validation, pathogen detection, genetic testing, and other disease research.
- (5)
- (36)
- (92)
- (18)
- (34)
- (2)
- (3)
- (8)
- (2)
- (1)
- (14)
- (38)
- (1)
- (2)
- (31)
- (2)
- (31)
- (7)
- (43)
- (18)
- (4)
- (1)
- (1)
- (52)
- (4)
- (9)
- (9)
- (55)
- (1)
- (1)
- (14)
- (19)
- (43)
- (37)
- (14)
- (3)
Filtered Search Results
Applied Biosystems™ AgPath-ID™ One-Step RT-PCR Reagents
AgPath-ID™ One-Step RT-PCR Reagents are designed for sensitive, robust amplification of RNA targets using a rapid single-tube TaqMan™ real-time reverse transcription PCR (RT-PCR) strategy.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Shipping Condition | Dry Ice |
---|---|
GC-Rich PCR Performance | High |
Fidelity (vs. Taq) | 25 X |
Description | Works on all AB platforms, but is optimized for the 7500. |
Reverse Transcriptase | ArrayScript™ |
Concentration | 25X |
PCR Method | 1-step RT-qPCR |
Detection Method | Primer-probe |
Polymerase | AmpliTaq Gold DNA Polymerase |
Format | Tube |
Product Type | One-Step RT-PCR Reagent |
Passive Reference Dye | ROX (Pre-mixed) |
For Use With (Equipment) | 7500 System, 7500 Fast System, 7900HT System, StepOne™, StepOnePlus™, ViiA™ 7 System, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio™ 7 Flex, QuantStudio 6 Pro, QuantStudio 7 Pro, QuantStudio™ 12k Flex |
Sample Type | RNA |
Reaction Speed | Standard |
Product Line | AgPath-ID™, Ambion™ |
Applied Biosystems™ VetMAX™ PRRSV 3.0 Controls
VetMAX™ PRRSV 3.0 Controls are for use in multiplex, real-time reverse transcription PCR (RT-PCR) assays targeting North American and European porcine reproductive and respiratory syndrome virus (PRRSV) and Xeno RNA.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Applied Biosystems™ VetMAX™ Xeno™ Internal Positive Control - VIC™ Assay
The VetMAX™ Xeno™ Internal Positive Control (IPC) - VIC™ Assay is a primer-probe mix that detects the Xeno internal positive control. The resultant Xeno data is used to determine the validity of diagnostic test results.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Shipping Condition | Dry Ice |
---|---|
Format | Kit |
Label or Dye | VIC |
Species | Not Species-Specific |
Product Line | VetMAX™, Xeno™ |
Applied Biosystems™ Power SYBR™ Green RNA-to-CT™ 1-Step Kit
The novel formulation reduces false positive results caused by primer dimers, significantly improves data accuracy, and provides reliable detection of low abundance targets.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Shipping Condition | Wet Ice |
---|---|
Purity or Quality Grade | UP (Ultra Pure) |
Reverse Transcriptase | ArrayScript™ UP |
For Use With (Application) | Gene Expression |
PCR Method | 1-step RT-qPCR |
Detection Method | SYBR |
Polymerase | AmpliTaq Gold DNA Polymerase |
Passive Reference Dye | ROX (Pre-mixed) |
For Use With (Equipment) | 7500 Fast System, 7500 System, 7900HT System, QuantStudio™ 12k Flex, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio™ 7, StepOne™, StepOnePlus™, ViiA™ 7 System |
Sample Type | RNA |
Reaction Speed | Standard |
Label or Dye | SYBR Green |
Run Time | Standard |
Product Line | RNA-to-CT™, SYBR™ |
Applied Biosystems™ TaqMan™ Advanced miRNA cDNA Synthesis Kit
Kit uses 3' poly-A tailing and 5' ligation of an adaptor sequence to extend the mature miRNAs present in the sample on each end prior to reverse transcription.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Applied Biosystems™ Detection Enhancer, for real-time PCR
Formulated to improve template amplification in real-time PCR (qPCR) workflows
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Shipping Condition | Dry Ice |
---|---|
GC-Rich PCR Performance | High |
Product Type | Detection Enhancer |
For Use With (Equipment) | 7500 System |
Sample Type | Viral Samples |
Reaction Speed | Standard |
For Use With (Application) | Real Time PCR (qPCR) |
PCR Method | 1-step RT-qPCR |
Product Line | Applied Biosystems™ |
Detection Method | Primer-probe |
Applied Biosystems™ TaqMan™ Exogenous Internal Positive Control Reagents
TaqMan™ Exogenous Internal Positive Control Reagents contain a pre-optimized internal positive control (IPC) with pre-designed primers and TaqMan™ probe.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
GC-Rich PCR Performance | Low |
---|---|
Format | Tube(s) |
Internal Probe Modification | TAMRA™ Quencher (3'), VIC™ (5') |
Product Type | Exogenous Internal Positive Control Reagent |
Reaction Speed | Standard |
Green Features | Sustainable packaging |
PCR Method | qPCR |
Product Line | TaqMan™ |
Applied Biosystems™ VetMAX™-Plus One-Step RT-PCR Kit
For use with VetMAX™ Reagents and VetMAX™ Controls.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Applied Biosystems™ TaqMan™ Reagents Starter Kit
TaqMan™ PCR Starter Kit is designed to detect and quantify Eukaryotic 18S rRNA sequence in human Raji cDNA using the TaqMan™ 5' nuclease assay with the TaqMan™ PCR Master Mix.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Sample Type | DNA (Genomic), cDNA |
---|---|
Reaction Speed | Standard |
For Use With (Application) | Gene Expression |
Detection Method | Primer-probe |
Applied Biosystems™ TrueMark™ Amplification Control I (1 x 105 copies/μL)
The TrueMark Amplification Control I for TrueMark plates contains a linearized multi-target plasmid pool with microbial target sequences used on TrueMark infectious disease research panels.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Applied Biosystems™ TaqMan™ Fast Reagent Starter Kit
Designed to detect and quantify Eukaryotic 18S rRNA sequence in cDNA samples using the TaqMan 5' nuclease assay, in fast thermal cycling mode.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Sample Type | DNA (Genomic), cDNA |
---|---|
Reaction Speed | Fast |
For Use With (Application) | Gene Expression |
Detection Method | Primer-probe |
Applied Biosystems™ VetMAX™-Plus Multiplex One Step RT-PCR Kit
For use with VetMAX™ Reagents and VetMAX™ Controls.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Applied Biosystems™ TrueMark™ Amplification Control I (5 x 107 copies/μL)
The TrueMark Amplification Control I for TrueMark plates contains a linearized multi-target plasmid pool with microbial target sequences used on TrueMark infectious disease research panels.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Applied Biosystems™ TaqMan™ MicroRNA Reverse Transcription Kit
Provides the necessary components for 200 reactions of optimal performance in TaqMan™ MicroRNA Assays.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Shipping Condition | Dry Ice |
---|---|
GC-Rich PCR Performance | High |
Fidelity (vs. Taq) | 10 X |
Reverse Transcriptase | MultiScribe™ |
Final Product Type | cDNA |
Concentration | 10X |
For Use With (Application) | miRNA analysis |
PCR Method | 2-step RT-qPCR |
Detection Method | Primer-probe |
Size (Final Product) | 200 bp or less |
Reaction Format | Separate Components |
Product Type | MicroRNA Reverse Transcription Kit |
Sample Type | RNA |
Reaction Speed | Fast |
Optimal Reaction Temperature | 42°C |
Product Line | TaqMan™ |
Invitrogen™ ROX Reference Dye
ROX Reference Dye is designed to normalize the fluorescent reporter signal in real-time quantitative PCR or RT-PCR.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Content And Storage | Store in freezer (-5° to -30°C). |
---|---|
Label or Dye | ROX |
Detection Method | Primer-probe |