Test
View, store, and share real-time data on a smartphone
Smart Technology Aperture Tubes are designed specifically for the Multisizer 4 or 4e Analyzer. The aperture allows extended sizing measurement range of 2% to 80% of the aperture diameter.
For Use With (Equipment) | Multisizer™ 4 or 4e Coulter Counters |
---|---|
Product Type | Aperature Tube |
Material | Glass |
Single Wavelength (SW) Laser Diffraction Particle Size Analyzer provides expanded measurement range from 0.40 μm to 3,500 μm. The DPS is capable of measuring dry powder samples, while the ULM analyzes samples suspended in aqueous or non-aqueous dilutents.
Particle Size | 0.40 μm to 3,500 μm |
---|---|
Model | LS 13 320 XR SW |
For Use With (Application) | Particle Size Analysis of Dry Powder, Aqueous, and Non-Aqueous Samples |
The Multisizer 4e Coulter Counter uses the Coulter Principle to detect particles via electrical zone sensing, regardless of the particle’s nature or optical properties. Therefore, the Coulter Counter is an ideal tool for detecting and counting a wide variety of particles.
Height (Metric) | 50.8 cm |
---|---|
Width (English) | 25 in. |
Model | Multisizer™ 4e |
Weight (English) | 170 lb. |
For Use With (Application) | Particle Counting and Detection |
Width (Metric) | 63.5 cm |
Power Supply | 100/210 VAC |
Weight (Metric) | 77 kg |
Height (English) | 20 in. |
Multiwavelength Particle Size Analyzer incorporates PIDS to provide a dynamic range down to 0.010 μm. The DPS is capable of measuring dry powder samples, while the ULM analyzes samples suspended in aqueous or non-aqueous dilutents.
For Use With (Equipment) | Requires Controller, and Standard LS/HiCap Vacuum Unit |
---|---|
Model | LS 13 320 XR MW |
For Use With (Application) | Particle Size Analysis of Dry Powder, Aqueous, and Non-Aqueous Samples |
For calibrating Coulter Counter Aperture Tubes, and verifying their performance.
Product Type | Particle Size Standard |
---|---|
For Use With (Application) | Calibration and Performance Verification |
Recommended for LS Series Instruments to verify instrument and module performance.
For Use With (Application) | Verifying Instrument and Module Performance |
---|
Smart Technology High Resolution Aperture Tubes are designed specifically for the Multisizer 4e Analyzer. For greater discrimination of particle size, high resolution tubes have an aperture thickness 120% greater than normal apertures which extends the time it takes for the particle to pass through.
For Use With (Equipment) | Multisizer™ 4e Coulter Counters |
---|---|
Product Type | High Resolution Aperature Tube |
Material | Glass |
Particle Size Controls for use with LS 13 320 XR Analyzers to verify instrument and module performance.
For Use With (Equipment) | LS 13 320 XR Analyzer |
---|---|
Product Type | Particle Size Control |
For Use With (Application) | Verifying Instrument and Module Perfomance |
Designed for use on the stage of the Multisizer 4e to ensure optimal fluid use and circulation with the locked platform height.
Utilize the Spigot Assembly for easy dispensing of ISOTON II and Coulter CLENZ Cleaning Agents.
Dry Powder System (DPS) Tubes are specifically designed for use with Dry Powder and Tornado Modules of LS 13 320 Series Analyzers to fit on the base of the module.
Adapter allows the proper alignment of a 5 mL Nalgene Sample Cup (6250-0005) on the Accuvette stage. Sample cups are crucial for precious samples, or when there is limited sample material available.
The HiCap HEPA Vacuum Unit is designed for use with the Dry Powder System (DPS) of the LS 13 320 XR Particle Size Analyzer. The Vacuum Unit delivers dry powder samples to the sensing zone in the optical bench of the LS 13 320 XR, all required connectors are included.
For Use With (Equipment) | LS 13 320 XR and Dry Powder System (DPS) |
---|
Designed for use with the LS 13 320 Particle Size Analyzer ALM Auto-Prep Station, which can hold up to 30 sample tubes. The barcode allows programming of the SOM to allow each sample to be automatically run with a designated SOM.