Promotional price valid on web orders only. Your contract pricing may differ. Interested in signing up for a dedicated account number?
Learn More

Agilent BioTek Synergy H1 Hybrid Multi-Mode Reader
GREENER_CHOICE

BioTek Synergy H1 is a modular multi-mode microplate reader, with monochromator-based optics and filter-based optics. For Research Use Only. Not for use in diagnostic procedures.

Specifications

Accuracy Absorbance: ±2 nm; Dispenser: ±1 μL or 2%
Certifications/Compliance CE and TUV marked. RoHS compliant.
CO2 Concentration Range 0 to 20%
Depth (Metric) 46.4 cm
Compatibility BioStack and Third Party Automation Compatible
View More Specs

Products 10
Catalog Number Mfr. No. Model Incubator Temperature Includes Price Quantity & Availability  
Catalog Number Mfr. No. Model Incubator Temperature Includes Price Quantity & Availability  
11120531
GREENER_CHOICE
View Documents
Agilent BioTek
SH1FSN
H1F 4-Zone Incubation to 45°C Full-light luminescence; Filter/dichroic fluorescence; Fluorescence polarization; Time resolved fluorescence; Filtered luminescence N/A N/A
This product is not available for sale online. Please contact Customer Service at 1-800-766-7000 or send email to cs.webemail@thermofisher.com to discuss your specific assay requirements.
BTH1FG
GREENER_CHOICE
View Documents
Agilent BioTek
SH1FGSN
H1FG 4-Zone Incubation to 45°C Compatible with gas controller; Full-light luminescence; Filter/dichroic fluorescence; Fluorescence polarization; Time resolved fluorescence; Filtered luminescence N/A N/A
This product is not available for sale online. Please contact Customer Service at 1-800-766-7000 or send email to cs.webemail@thermofisher.com to discuss your specific assay requirements.
11-120-533
GREENER_CHOICE
View Documents
Agilent BioTek
SH1MSN
H1M 4-Zone Incubation to 45°C Monochromator fluorescence; Monochromator absorbance; Full-light luminescence; Time resolved fluorescence N/A N/A
This product is not available for sale online. Please contact Customer Service at 1-800-766-7000 or send email to cs.webemail@thermofisher.com to discuss your specific assay requirements.
11-120-535
View Documents
Agilent BioTek
SH1MFSN
H1MF 4-Zone Incubation to 45°C Monochromator fluorescence; Monochromator absorbance; Full-light luminescence; Filter/dichroic fluorescence; Fluorescence polarization; Time resolved fluorescence; Filtered luminescence N/A N/A
This product is not available for sale online. Please contact Customer Service at 1-800-766-7000 or send email to cs.webemail@thermofisher.com to discuss your specific assay requirements.
BTH1MG
GREENER_CHOICE
View Documents
Agilent BioTek
SH1MGSN
H1MG 4-Zone Incubation to 45°C Compatible with gas controler; Monochromator fluorescence; Monochromator absorbance; Full-light luminescence; Time resolved fluorescence N/A N/A
This product is not available for sale online. Please contact Customer Service at 1-800-766-7000 or send email to cs.webemail@thermofisher.com to discuss your specific assay requirements.
BTH1MFG
GREENER_CHOICE
View Documents
Agilent BioTek
SH1MFGSN
H1MFG 4-Zone Incubation to 45°C Compatible with gas controller; Monochromator fluorescence; Monochromator absorbance; Full-light luminescence; Filter/dichroic fluorescence; Fluorescence polarization; Time resolved fluorescence; Filtered luminescence N/A N/A
This product is not available for sale online. Please contact Customer Service at 1-800-766-7000 or send email to cs.webemail@thermofisher.com to discuss your specific assay requirements.
BTH1M2
View Documents
Agilent BioTek
SH1M2SN
H1M2 4-Zone Incubation to 70°C Variable bandwidth monochromator fluorescence; Monochromator absorbance; Full-light luminescence; Time resolved fluorescence N/A N/A
This product is not available for sale online. Please contact Customer Service at 1-800-766-7000 or send email to cs.webemail@thermofisher.com to discuss your specific assay requirements.
BTH1M2F
View Documents
Agilent BioTek
SH1M2FSN
H1M2F 4-Zone Incubation to 70°C Variable bandwidth monochromator fluorescence; Monochromator absorbance; Full-light luminescence; Filter/dichroic fluorescence; Fluorescence polarization; Time resolved fluorescence; Filtered luminescence N/A N/A
This product is not available for sale online. Please contact Customer Service at 1-800-766-7000 or send email to cs.webemail@thermofisher.com to discuss your specific assay requirements.
BTH1M2FG
View Documents
Agilent BioTek
SH1M2FGSN
H1M2FG 4-Zone Incubation to 70°C Compatible with gas controller; Variable bandwidth monochromator fluorescence; Monochromator absorbance; Full-light luminescence; Filter/dichroic fluorescence; Fluorescence polarization; Time resolved fluorescence; Filtered luminescence N/A N/A
This product is not available for sale online. Please contact Customer Service at 1-800-766-7000 or send email to cs.webemail@thermofisher.com to discuss your specific assay requirements.
BTH1M2G
GREENER_CHOICE
View Documents
Agilent BioTek
SH1M2GSN
H1M2G 4-Zone Incubation to 70°C Compatible with gas controller; Variable bandwidth monochromator fluorescence; Monochromator absorbance; Full-light luminescence; Time resolved fluorescence N/A N/A
This product is not available for sale online. Please contact Customer Service at 1-800-766-7000 or send email to cs.webemail@thermofisher.com to discuss your specific assay requirements.
Description

Description

BioTek Synergy H1 is a modular multi-mode microplate reader, with monochromator-based optics and filter-based optics. The patented Hybrid Technology offers flexibility and sensitivity across a broad range of applications. The modular platform allows upgrading to expand functionality as your laboratory workflows change

Synergy H1 offers continuously variable bandwidth monochromators for fluorescence excitation and emission wavelength selection. Fluorescence bandwidth can be set between 9 and 50 nm, in 1 nm increments, allowing users to fully optimize reader settings to drive the best assay performance compared to fixed bandwidth systems.

Certifications

CE marked

Specifications

Specifications

Absorbance: ±2 nm; Dispenser: ±1 μL or 2%
0 to 20%
BioStack and Third Party Automation Compatible
11 sec. (96 wells), 22 sec. (384 wells)
0 to 4 OD
13 in.
33 cm
2 Syringe Pumps
130 W max.
2.5 to 4 pM monochromators, 0.25 pM filters fluorescence, 20 amol ATP monochromator, 10 amol ATP filter luminescence, 1.2 mP fluorescence polarization, Europium 40 fM with filters, 1200 fM with monos time resolved fluorescence
<55 lb.
14.8 in.
6- to 384-well Plates, Take3 Micro-volume Plates
Gen5 Microplate Reader and Imager Software, Gen5 Secure for 21 CFR Part 11 compliance (option)
End Point, Kinetic, Spectral Scanning, Well Area Scanning
CE and TUV marked. RoHS compliant.
46.4 cm
18.3 in.
Linear, Orbital, Double Orbital
5 to 1000 μL, 1 μL increments
50/60 Hz
Proprietary Hybrid Technology
Multi-Mode Microplate Reader
±0.1% (CO2 and O2)
Fluorescence Intensity Monochromator: 250 to 700 nm (900 nm option), Fluorescence Polarization: 280 to 700 nm (850 nm option)
25 kg
37.5 cm
Photodiode, PMT
Xenon Flash
SDS
Documents