Fisherbrand™ accuCap™ Capillary Junction pH Combination Electrodes - Plastic Body, Gel-Filled - Mercury-Free

Large junction for increased flow, minimal clogging

Catalog No. 13-620-132


Edge
Add to Cart

Description

Description

Large junction for increased flow, minimal clogging

Better junction

  • Single-pore capillary junction is ∽200 times larger than typical ceramic junctions
  • Almost impossible to clog, even in difficult samples
  • Increased electrolyte flow, greater contact between sample and reference, fast and stable readings
Better reference design
  • Double junction design for enhanced performance
  • Diffusion barrier separates silver chloride reservoir from reference electrolyte
  • Permits use of silver-free electrolytes, prevents silver chloride loss from temperature-induced variations
  • Result: an extremely stable reference potential, providing long electrode life
Most accurate
  • Testing at German Federal Physical Technical Institute in Braunschweig determined this electrode design to be the most accurate laboratory electrode
  • See Traceability of pH measurement by Petra Spitzer; ISBN 3-89429-877-4 or SSN 0947-7063

  • Standard plastic body and glass pH membrane
  • Solid polymer-gel electrolyte offers the advantages of the accuCap system in a maintenance-free version
  • Provides a more stable matrix than other gelled electrode reference systems
  • Gives reliable results in very dirty, ion-weak or protein samples
  • Reliable even at low pH or in presence of some organic solvents (check compatibility before measuring)

TRUSTED_SUSTAINABILITY
Specifications

Specifications

Purple
Open
0 to 14
pH Combination Electrode
pH
32°F to 140°F
1 Year
120 mm
12 mm
BNC
Plastic
0°C to 60°C
Polymer gel
pH meter
0°C to 60°C
4.7 in.
0.47 in.
Product Suggestions

Product Suggestions

SDS
Documents

Documents

Product Certifications
Promotions

Promotions

Provide Content Correction

We continue to work to improve your shopping experience and your feedback regarding this content is very important to us. Please use the form below to provide feedback related to the content on this product.

Product Title

By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.

Cancel Submit