Mettler Toledo™ DSC 5+ Differential Scanning Calorimeter

Differential scanning calorimetry (DSC) measures enthalpy changes in a material due to changes in physical and chemical properties as a function of temperature or time. The DSC 5+ sets the new standard, delivering a superior performing and more productive DSC.

Supplier:  Mettler Toledo™ 30877114

 View more versions of this product

Catalog No. 01-338-204


Explore available promotions
Add to Cart

Description

Description

  • FlexMode™: choose power compensation or heat flux mode
  • Power compensation: provides outstanding resolution for separating close-lying effects
  • MultiSTAR™ sensor with 136 thermocouples: exceptional sensitivity for the measurement of weak effects
  • Patented electrical heat flow adjustment: saves time and ensures excellent measurement accuracy
  • Time-saving FlexCal™ adjustment: guarantees accurate results under all measurement conditions
  • Innovative robot with gas-purged sample chamber: protects samples from the environment and operates reliably around the clock
  • Unrivalled modular concept: tailor-made solutions for current and future needs
  • Huber cooling system required for use with the DSC 5+ (item #30857474 or 30857475)

Note: This is a configurable instrument; additional METTLER TOLEDO accessories and software are required. Please contact your local Fisher Scientific Sales Representative to discuss the best configuration for your application.

TRUSTED_SUSTAINABILITY
Specifications

Specifications

Differential Scanning Calorimeter
Melting Behavior, Crystallization and Nucleation, ad Polymorphism, Phase Diagrams and Composition, Glass Transitions, Curing, Stability, Effects of Plasticizers, Reaction and Transition Enthalpies, Heat Capacity and Heat Capacity Changes
Automatic
-150°C to 700°C
22 in.
36 in.
± 0.2 K
22 in.
Product Suggestions

Product Suggestions

SDS
Documents

Documents

Product Certifications
Promotions

Promotions

Product Content Correction

Your input is important to us. Please complete this form to provide feedback related to the content on this product.

Product Title

By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.