Test
Thermo Scientific™ TraceGOLD TG-XLBMS GC Columns offer a low polarity, low bleed column suitable for a wide range of applications.
Max. Temperature | 340/360°C |
---|---|
Stationary Phase | TraceGOLD™ TG-XLBMS |
Polarity | Low-Polar |
Separate ethane, ethylene and acetylene consistently with the intermediate polarity PLOT column with essentially no particle release.
Max. Temperature | Up to 250°C |
---|---|
Stationary Phase | TracePLOT™ TG-BOND Q+ |
Polarity | Mid-Polar |
For Use With (Application) | GC for the Separation of Ethane, Ethylene, and Acetylene to Baseline |
Determine methanol, fatty acid methyl esters (FAMEs) and glycerides in biodiesel analysis with high performance and reproducibility.
Max. Temperature | 300/320°C |
---|---|
Stationary Phase | Trace™ TR-BioDiesel |
USP Type | G1, G2, G38 |
Product Line | TRACE |
Analyze a wide range of polar compounds with this low-bleed, general purpose, high polarity GC column.
Stationary Phase | Trace™ TR-WAX |
---|---|
Polarity | Polar |
USP Type | G16, G20 |
Ensure excellent column-to-column reproducibility using the Thermo Scientific™ TraceGOLD™ TG-WaxMT GC Columns.
Max. Temperature | 260°C |
---|---|
Stationary Phase | TraceGOLD™ TG-WAXMS |
Polarity | Polar |
Temperature Range | 40°C°C to 260°C |
For Use With (Application) | GC for EPA Method 603 for Acrolein/Acrylonitrile,GC for Fatty Acid Methyl Esters (FAMEs), Flavor Compounds, Essential Oils, Amines, Solvents, and Xylene Isomers |
USP Type | G14, G15, G16, G20, G39 |
Extend column life with the integrated guard of the this GC column.
Max. Temperature | 330/350°C (Standard Columns), 430°C (Metal Columns) |
---|---|
Stationary Phase | TraceGOLD™ TG-1 MS |
Length (Metric) | 30 m |
Polarity | Non-Polar |
For Use With (Application) | GC/MS for Optimal Signal-to-Noise Ratio, Sensitivity, and MS Integrity |
USP Type | G2 |
Use the highly inert and efficient TraceGOLD TG-VVOC B GC columns for very volatile organic compounds.
Optimize separation when analyzing active environmental compounds with this low-bleed GC column with superior inertness.
Protect your analytical column from damage and contamination from nonvolatile materials.
Achieve higher thermal stability and increased efficiency using these columns.
Max. Temperature | 220/240°C |
---|---|
Stationary Phase | TraceGOLD™ TG-225 MS |
Polarity | Polar |
USP Type | G7, G19 |
Resolve compounds that phenyl and cyano phases cannot using a low-bleed GC column with an exceptionally inert phase.
Max. Temperature | 320/340°C |
---|---|
Stationary Phase | TraceGOLD™ TG-200 MS |
Polarity | Mid-Polar |
USP Type | G6 |
Features a mix of cyano and phenyl groups for increased polarity and a different elution order relative to less polar columns.
Max. Temperature | 260/280°C |
---|---|
Stationary Phase | TraceGOLD™ TG-1701 MS |
Polarity | Mid-Polar |
USP Type | G46 |
Extend column lifetime and get more consistent results over a longer period of time.
Max. Temperature | 330/350°C (Standard Columns), 430°C (Metal Columns) |
---|---|
Stationary Phase | TraceGOLD™ TG-5 MS |
Polarity | Low-Polar |
Temperature Range | -60°C to +330/350°C |
For Use With (Application) | Active Compounds Analysis,GC/MS for Analysis of Active Compounds |
USP Type | G27, G36 |
Achieve consistent results with this low-bleed, stable column. Choose this nonpolar GC column for optimal signal-to-noise ratio, sensitivity, and MS integrity.
Polarity | Non-Polar |
---|
Thermo Scientific™ TraceGOLD TG-5MS AMINE GC Column enables analysis of ppm levels of amines without column priming.
Max. Temperature | 300/315°C |
---|---|
Stationary Phase | TraceGOLD™ TG-5 MS Amine |
Polarity | Low-Polar |
For Use With (Application) | GC/MS for Analysis of Amines and Other Basic Compounds, Including Alkylamines, Diamines, Triamines, and Ethanolamines,GC/MS for Nitrogen-Containing Heterocyclics |