Electrochemistry Meters
Electrochemistry Meters
Filtered Search Results
METTLER TOLEDO™ SevenExcellence™ S475 pH/Conductivity/ISE Benchtop Meter
The S475 meter performs pH, conductivity, resistivity, ion selective, salinity, TDS, Redox/ORP, and ISFET measurements. It can be expanded with an additional module to measure DO/BOD. It has an intuitive touchscreen, measurement shortcuts, and can export data to a printer, Excel, or LIMS system.
Fisherbrand™ accumet™ AB200 Benchtop pH/Conductivity Meters
Provides intuitive, simple operation and high accuracy measurements in a compact, affordable meter. Fisherbrand accumet AB200 pH/conductivity meter combines the benefits of a pH meter and conductivity meter in one easy to use, reliable measurement system. The large backlit display offers great visibility in laboratory environments.
Range (Resistivity) | 2 W to 20 MW |
---|---|
Resolution (pH) | 0.1/0.01/0.001 |
Cell Constant | 0.010 to 10.000 |
Range (pH) | -2 to 20 |
Accuracy (pH) | ±0.002 |
Range (Salinity) | 0 to 80 ppt |
Data Management Details | Manual, timed (selectable every 3 to 3600 sec.), printer or CSV format |
Display Type | LCD |
Accuracy (Salinity) | ± 1% full scale |
Resolution (Salinity) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
Voltage | 100/240V |
Accuracy (Conductivity) | ±1% FS |
Resolution (mV) | 0.1mV |
Data Points | 500 |
Inputs | BNC, ATC |
Calibration Points (Conductivity) | Automatic (4 points), maximum 1/range, manual (5 points), maximum 1/range |
Accuracy (mV) | ±0.2 mV |
Warranty | 3 Years |
Temperature Accuracy | ±0.3°C |
Resolution (Resistivity) | 0.01/0.1W, 0.001/0.1kW, 0.01MW |
Resolution (Conductivity) | 0.01/0.1μS, 0.001/0.01/0.1mS |
Range (Conductivity) | 0 μS to 500 mS |
Accuracy (Resistivity) | ± 1% full scale |
Range (TDS) | 0 ppm to 500 ppt (at TDS factor 1) |
Resolution (TDS) | 0/0.1ppm, 001/01/0.1ppt |
Accuracy (TDS) | ± 1% full scale |
Outputs | RS232 (phono plug), mini-B USB, stirrer |
Frequency | 50/60Hz |
Calibration Points (pH) | Up to 6 preset or 5 custom |
Range (mV) | ±2000 mV |
Temperature Resolution | 0.1°C |
Fisherbrand™ Traceable™ Conductivity/TDS Meter Pen
Easy-to-use, waterproof conductivity/TDS meter designed for routine analysis and quality control. Simply turn on, insert, and simultaneously read result and temperature.
Fisherbrand™ Traceable™ Conductivity Meter Pen
Easy-to-use, waterproof conductivity meter designed for routine analysis and quality control. Simply turn on, insert, and simultaneously read result and temperature.
Fisherbrand™ accumet™ AB250 Benchtop pH/ISE Meters
Provides intuitive, simple operation and high accuracy measurements in a compact, affordable meter. Fisherbrand accumet AB250 pH/ISE meter provides flexible measurements of pH or ion concentration using an ion selective electrode (ISE) in one easy to use, reliable measurement system.
Accuracy (mV) | ±0.2 mV |
---|---|
Accuracy (ISE) | 0.5% full scale (monovalent ion), 1% full scale (divalent ion) |
Warranty | 3 Years |
Temperature Accuracy | ±0.3°C |
Calibration Points (ISE) | 2 to 6 points from one of following group, 0.001, 0.01, 0.1, 1, 10, 100, 0.01, 0.1, 1, 10, 100, 1000 |
Resolution (pH) | 0.1/0.01/0.001 |
Range (pH) | -2 to 20 |
Resolution (ISE) | 0.001/0.01/0.1/1 (automatic) |
Accuracy (pH) | ±0.002 |
Range (ISE) | 0.001 to 19999 (±2000) |
Data Management Details | Manual, timed (selectable every 3 to 3600 sec.), printer or CSV format |
Display Type | LCD |
Voltage | 100/240V |
Resolution (mV) | 0.1mV |
Outputs | RS232 (phono plug), mini-B USB, stirrer |
Frequency | 50/60Hz |
Data Points | 500 |
Calibration Points (pH) | Up to 6 preset or 5 custom |
Range (mV) | ±2000 mV |
Inputs | BNC, ATC |
Temperature Resolution | 0.1°C |
Fisherbrand™ Traceable™ Expanded Range Conductivity Meter
Ideal for checking the purity of water from stills, deionizers, and reverse osmosis, testing laboratory glassware rinsing, measuring total dissolved solids, and making solutions.
Thermo Scientific™ Orion Star™ A215 pH/Conductivity Benchtop Multiparameter Meter
Reliably measure pH, conductivity and temperature with our pH/conductivity benchtop meter for advanced lab analysis and interfacing.
Salinity Measurement Modes | Practical salinity (psu) or natural sea water (ppt) |
---|---|
Range (Resistivity) | 2 ohm to 100.0 meg-ohm |
Memory | Non-volatile memory preserves data log, calibration log and meter settings |
Resolution (pH) | 0.1/0.01/0.001 |
Languages | English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update |
Power Supply | Universal AC adapter (included) or 4 AA batteries (sold separately) |
Data Management Details | Transfer single, range or all data points to printer or computer |
Battery Life | 800 hr. |
Display Type | LCD Graphic, Backlit |
Resolution (mV) | 0.1mV |
Data Points | 2000 with date and time stamp |
Temperature Probe Calibration | 1 point temperature offset calibration |
Certifications/Compliance | CE, TUV 3-1, FCC Class A |
Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
Warranty | 3 Year Meter |
Temperature Accuracy | ±0.1°C |
Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
Resolution (Conductivity) | 0.001 μS minimum, auto ranging up to 4 significant digits |
Range (Conductivity) | 0.001 μS/cm to 3000 mS/cm |
Log Function Type | Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m |
Battery Type | 4 AA (sold separately) |
Relative Humidity Range | 5 to 85 %, non-condensing |
Dimensions (L x W x H) | 24cm x 18cm x 11cm (9.5 in. x 7.1 in. x 4.3 in.) |
Accuracy (TDS) | 0.5% of reading ±1 digit |
Temperature Selection | Manual or automatic with ATC temperature probe |
Keypad | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys |
Outputs | USB, RS232 |
Temperature Range (English) | 22.0°F to 221.0° F |
Range (Relative mV) | ±2000.0 mV |
Calibration Points (pH) | 1 to 5 |
Backlight Option | Yes, selectable |
Range (mV) | ±2000.0 mV |
Range (ORP) | ±2000.0 mV |
Methods | 10 per channel with password protection |
Cell Constant | 0.001 to 199.9cm-1 |
Temperature (Metric) Reference | 5, 10, 15, 20, 25°C |
Range (pH) | -2.000 to 20.000 |
TDS Factor Range | Linear (0.02 to 9.99) |
Channels | 2 |
Accuracy (pH) | ±0.002 |
Range (Salinity) | 0.06 to 80.00 psu, 0.05 to 42.00 ppt |
Temperature Compensation | Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off |
Accuracy (Salinity) | 0.5% of reading ±1 digit |
Resolution (Salinity) | 0.01 psu or 0.01 ppt minimum, auto ranging |
Accuracy (Conductivity) | 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS |
Inputs | BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (conductivity sensor with built-in temperature or ATC temperature probe), stirrer input (stirrer probe) |
Weight (Metric) | 0.9 kg |
Calibration Points (Conductivity) | Up to 5 |
Temperature (English) Operating | 41°F to 113°F (ambient) |
Resolution (Resistivity) | 1 ohm or 0.1 meg-ohm, auto ranging |
Isopotential Point | 7.000pH |
Accuracy (Resistivity) | 0.5% of reading ±1 digit |
AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. 1010003) |
Range (TDS) | 0.001 ppm to 200.0 ppt |
Resolution (TDS) | 0.001 ppm minimum, auto ranging up to 4 significant digits |
Calibration | pH with calibration editing option, relative mV (RmV), ORP, conductivity with calibration editing op |
Calibration Points | 1 point relative mV (RmV) mode, 1 point ORP mode |
Alarm Output | High/low limit alarm, calibration due alarm |
IP Rating | IP 54 |
Model | Orion Star A215 pH/mV/RmV/ORP/Conductivity/TDS/Salinity/Resistivity/Temperature Benchtop Meter |
Weight (English) | 2 lb. |
Temperature (Metric) Operating | 5°C to 45°C (ambient) |
Temperature Range (Metric) | -5.0°C to +105.0°C |
Temperature Resolution | 0.1°C, 0.1°F |
Thermo Scientific™ Orion Star™ A212 Conductivity Benchtop Meter
Reliably measure conductivity, TDS, salinity, resistivity and temperature with this conductivity benchtop meter for advanced lab analysis.
Salinity Measurement Modes | Practical salinity (psu) or natural sea water (ppt) |
---|---|
Range (Resistivity) | 2 ohm to 100.0 megohm |
Memory | Non-volatile memory preserves data log, calibration log and meter settings |
Languages | English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update |
Measurement Modes | Conductivity,TDS,Salinity,Resistivity with Temperature |
Power Supply | Universal AC adapter (included) or 4 AA batteries (sold separately) |
Battery Life | 800 hr. |
Data Management Details | Transfer single, range or all data points to printer or computer |
Display Type | Graphic LCD with Backlight |
Data Points | 2000 with date and time stamp |
Certifications/Compliance | CE, TUV 3-1, FCC Class A |
Temperature Probe Calibration | 1 point temperature offset calibration |
Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
Warranty | 3 Year Meter |
Resolution (Conductivity) | 0.001 μS minimum, auto ranging up to 4 significant digits |
Range (Conductivity) | 0.001 μS/cm to 3000 mS/cm |
Log Function Type | Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m |
Battery Type | 4 x AA (sold separately) |
Relative Humidity Range | 5 to 85%, non-condensing |
Dimensions (L x W x H) | 24 x 18 x 11 cm (9.5 x 7.1 x 4.3 in.) |
Accuracy (TDS) | 0.5% of reading ±1 digit |
Temperature Selection | Manual or automatic with ATC temperature probe |
Keypad | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys |
Outputs | USB, RS232 |
Backlight Option | Yes, selectable |
Compatible Probes | 2-cell or 4-cell conductivity sensors with built-in temperature |
Methods | 10 per channel with password protection |
Cell Constant | 0.001 to 199.9cm-1 |
Temperature (Metric) Reference | 5, 10, 15, 20, 25°C |
Channels | 1 |
TDS Factor Range | Linear (0.02 to 9.99) |
Range (Salinity) | 0.06 to 80.00 psu, 0.05 to 42.00 ppt |
Temperature Compensation | Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off wit |
Accuracy (Salinity) | 0.5% of reading ±1 digit |
Resolution (Salinity) | 0.01 psu or 0.01 ppt minimum, auto ranging |
Accuracy (Conductivity) | 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS |
Inputs | 8 pin MiniDIN (conductivity sensor with built-in temperature), stirrer input (stirrer probe) |
Accuracy (Temperature) | ±0.1°C |
Weight (Metric) | 0.9 kg |
Calibration Points (Conductivity) | 5 |
Temperature (English) Operating | 41°F to 113°F (ambient) |
Resolution (Resistivity) | 1 ohm or 0.1 megohm, auto ranging |
Accuracy (Resistivity) | 0.5% of reading ±1 digit |
AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. 1010003) |
Resolution (TDS) | 0.001 ppm minimum, auto ranging up to 4 significant digits |
Calibration | Conductivity with calibration editing option and temperature |
Alarm Output | High/low limit alarm, calibration due alarm |
IP Rating | IP54 |
Model | Orion Star A212 Conductivity/TDS/Salinity/Resistivity/Temperature Benchtop Meter |
Weight (English) | 2 lb. |
Resolution (Temperature) | 0.1°C (0.1°F) |
Temperature (Metric) Operating | 5°C to 45°C (ambient) |
Temperature Range (Metric) | -5°C to +105°C |
Fisherbrand™ accumet™ XL200 Benchtop pH/Conductivity Meters
Provide advanced measurements with simple operation and offer a large, vivid color touch-screen display that allows for dynamic functionality. Fisherbrand accumet XL200 pH/Conductivity benchtop meters offer advanced features with simple operation to help ensure your measurements are reliable and your laboratory processes are efficient.
Length (Metric) | 24.6 cm |
---|---|
Range (Resistivity) | 3 W to 100 MW over 4 ranges: 0 to 20 kW, 20 to 200 kW, 200 kW to 2 MW, 2 to 100 MW |
Detection Range | Multiple |
Length (English) | 9.68 in. |
Resolution (pH) | 0.1/0.01/0.001 |
Cell Constant | 0.01 to 10 |
Range (pH) | -2 to 20 |
Width (Metric) | 17.3 cm |
Accuracy (pH) | ±0.002 |
Range (Salinity) | 0 to 80 ppt |
Accuracy | Multiple |
Data Management Details | 3 to 86400 sec. |
Display Type | LCD |
Accuracy (Salinity) | ± 1% full scale |
Resolution (Salinity) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
Voltage | 100/240V |
Accuracy (Conductivity) | ±1% FS |
Resolution (mV) | 0.1mV |
Data Points | 2000 |
Certifications/Compliance | NIST, ISO, FDA, USDA, EPA |
Inputs | BNC, ATC |
Weight (Metric) | 1.13 kg |
Height (English) | 3.89 in. |
Calibration Points (Conductivity) | Automatic (4 points), maximum 1/range, manual (5 points), maximum 1/range |
Height (Metric) | 9.9 cm |
Accuracy (mV) | ±0.2 mV |
Warranty | 3 Years |
Temperature Accuracy | ±0.2°C |
Resolution (Resistivity) | 0.01/0.1W, 0.001/0.1kW, 0.01MW |
Resolution (Conductivity) | 0.001/0.01/0.1mS |
Range (Conductivity) | 0 to 500 mS |
Accuracy (Resistivity) | ± 1% full scale |
Range (TDS) | 0.050 ppm to 500 ppt (at TDS factor 1.00) |
Resolution (TDS) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
Dimensions (L x W x H) | 24.6 x 17.3 x 9.9cm (9.7 x 6.8 x 3.9 in.) |
Accuracy (TDS) | ± 1% full scale |
Outputs | RS232, USB-A, Mini-B USB, RJ45, stirrer port (2) |
Frequency | 50/60Hz |
Calibration Points (pH) | Up to 6 preset or 5 custom |
Weight (English) | 2.5 lb. |
Range (mV) | ±2000 mV |
Temperature Resolution | 0.1°C |
Resolution | Multiple |
Fisherbrand™ accumet™ XL500 Benchtop Dual pH/ISE and Conductivity Meters
Provide advanced measurements with simple operation and offer a large, vivid color touch-screen display that allows for dynamic functionality. Fisherbrand accumet XL500 dual pH/ISE/conductivity benchtop meters offer advanced features with simple operation to help ensure your measurements are reliable and your laboratory processes are efficient.
Length (Metric) | 24.6 cm |
---|---|
Range (Resistivity) | 3 W to 100 MW over 4 ranges: 0 to 20 kW, 20 to 200 kW, 200 kW to 2 MW, 2 to 100 MW |
Detection Range | Multiple |
Length (English) | 9.68 in. |
Resolution (pH) | 0.1/0.01/0.001 |
Cell Constant | 0.01 to 10 |
Range (pH) | -2 to 20 |
Width (Metric) | 17.3 cm |
Resolution (ISE) | 2/3/4 Digits |
Accuracy (pH) | ±0.002 |
Range (ISE) | ±2000 mV |
Range (Salinity) | 0 to 80 ppt |
Accuracy | Multiple |
Data Management Details | 3 to 86400 sec. |
Display Type | LCD |
Accuracy (Salinity) | ± 1% full scale |
Resolution (Salinity) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
Voltage | 100/240V |
Accuracy (Conductivity) | ±1% FS |
Resolution (mV) | 0.1mV |
Data Points | 2000 |
Certifications/Compliance | NIST, ISO, FDA, USDA, EPA |
Inputs | 2 BNC, 2 ATC |
Weight (Metric) | 1.13 kg |
Height (English) | 3.89 in. |
Calibration Points (Conductivity) | Automatic (4 points), maximum 1/range, manual (5 points), maximum 1/range |
Height (Metric) | 9.9 cm |
Accuracy (mV) | ±0.2 mV |
Accuracy (ISE) | 0.5% full scale (monovalent ion), 1% full scale (divalent ion) |
Warranty | 3 Years |
Temperature Accuracy | ±0.3°C |
Calibration Points (ISE) | 2 to 6 |
Resolution (Resistivity) | 0.01/0.1W, 0.001/0.1kW, 0.01MW |
Resolution (Conductivity) | 0.001/0.01/0.1mS |
Range (Conductivity) | 0 to 500 mS |
Accuracy (Resistivity) | ± 1% full scale |
Range (TDS) | 0.050 ppm to 500 ppt (at TDS factor 1.00) |
Resolution (TDS) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
Dimensions (L x W x H) | 24.6 x 17.3 x 9.9cm (9.7 x 6.8 x 3.9 in.) |
Accuracy (TDS) | ± 1% full scale |
Outputs | RS232, USB-A, Mini-B USB, RJ45, stirrer port (2) |
Frequency | 50/60Hz |
Calibration Points (pH) | Up to 6 preset or 5 custom |
Weight (English) | 2.5 lb. |
Range (mV) | ±2000 mV |
Temperature Resolution | 0.1°C |
Resolution | Multiple |
Mettler Toledo™ pH/Conductivity Meter SevenDirect SD23
The SevenDirect SD23 is an accurate and flexible benchtop meter for the determination of pH and conductivity - either separately or simultaneously. The instrument is the replacement of the SevenCompact and is delivered with an EasyPlace sensor arm.
Accuracy (mV) | 0.1 mV |
---|---|
Temperature Accuracy | ±0.1°C between 0°C and 100°C |
Memory | 2000 Standard Measurements |
Range (Conductivity) | 0.001 μS/cm to 2000 mS/cm |
Resolution (pH) | 0.1, 0.01, 0.001 |
Channels | Dual-channel |
Accuracy (pH) | 0.002 |
Dimensions (L x W x H) | 195 x 205 x 65 mm |
Data Management Details | PC, Printer, USB Stick |
Display Type | Color TFT |
IP Rating | IP54 |
Accuracy (Conductivity) | 0.5 % |
Resolution (mV) | 1, 0.1 mV |
Temperature Range (English) | -22°F to +266°F |
Weight (English) | 1.9 lb. |
Temperature Range (Metric) | -30°C to +130°C |
Range (mV) | -2000 to 2000 mV |
Weight (Metric) | 850 g |
Temperature Resolution | 0.1°C |
Resolution (ORP) | 1, 0.1 |
METTLER TOLEDO™ SevenExcellence™ S470 pH/Conductivity Benchtop Meter
The S470 meter measures pH, conductivity, resistivity, redox/ORP, TDS, salinity, and ISFET. It can be expanded with additional modules to measure dissolved oxygen, BOD, and ISE. It has an intuitive touchscreen, measurement shortcuts, and can export data to a printer, Excel file, or LIMS system.
Range (Resistivity) | 0.01 to 100megohm/cm |
---|---|
Resolution (pH) | 0.001/0.01/0.1 |
Range (pH) | -2 to 20 |
Resolution (ISE) | 0.001 to 1 |
Accuracy (pH) | ±0.002 |
Range (ISE) | 0 to 999999mg/L |
Range (Salinity) | 0 to 80 ppt |
Display Type | TFT |
Resolution (Salinity) | 0.001 to 1 |
Accuracy (Conductivity) | ±0.5% |
Resolution (mV) | 0.1/1mV |
Data Points | 20,000 |
Calibration Points (Conductivity) | 13 Pre defined and 20 user defined standard |
Accuracy (mV) | ±0.1mV |
Temperature Accuracy | ±0.1°C |
Calibration Points (ISE) | Max. 5 points, 8 pre defined and 20 user defined buffer group |
Resolution (Resistivity) | 0.001 to 1 |
Resolution (Conductivity) | 0.001μS/cm to 2000mS/cm |
Range (Conductivity) | 0.001 μS/cm to 2000 mS/cm |
Range (TDS) | 0.001 mg/L to 1000 g/L |
Resolution (TDS) | 0.001 to 1 |
Outputs | RS232, USB-A, USB-B, LAN, Mini-LTW, Mini-DIN, BNC, Cinch/RCA |
Calibration Points (pH) | Max. 5 points, 8 pre defined and 20 user defined buffer group |
Temperature Range (Metric) | -30°C to +130°C |
Range (mV) | -2000 to 2000 mV |
Temperature Resolution | 0.1°C |
OHAUS™ Aquasearcher™ Conductivity Meter AB33EC
The Aquasearcher™ Conductivity Meter AB33EC is a highly reliable benchtop meter designed to measure conductivity, total dissolved solids (TDS), salinity, and resistivity with temperature measurements.
Display Type | LCD One-line Dot Matrix |
---|---|
Range (Resistivity) | 1 to 100 MΩ-cm |
Range (Conductivity) | 0.001 μS/cm minimum, auto-range |
Accuracy (Conductivity) | ±0.5% Reading ±2 Least Significant Digit |
Outputs | RS232, USB Device (Included) |
Data Points | 1000 Sets |
Measurement Modes | Auto-stop,Continuous |
Temperature Range (Metric) | -5°C to +110°C |
Range (Salinity) | 0.01 psu minimum, auto-range |
Fisherbrand™ Traceable™ Dual-Display Conductivity Meter
Measures conductivity and temperature; includes NIST™ traceability certificate.
Fisherbrand™ Traceable™ Portable Dissolved Oxygen Meter