Test
Achieve consistent, reproducible separation of CO2, methane and 02/N2/CO with the non-polar PLOT column with essentially no particle release.
Max. Temperature | Up to 300/320°C |
---|---|
Stationary Phase | TracePLOT™ TG-BOND Q |
Polarity | Non-Polar |
Thermo Scientific™ TraceGOLD TG-XLBMS GC Columns offer a low polarity, low bleed column suitable for a wide range of applications.
Max. Temperature | 340/360°C |
---|---|
Stationary Phase | TraceGOLD™ TG-XLBMS |
Polarity | Low-Polar |
Analyze organochlorine pesticides and herbicides with ultra low bleed, superior sensitivity, excellent peak shape and the highest levels of reproducibility.
Max. Temperature | 340°C |
---|---|
Polarity | Non-Polar |
Identify organic acids with high performance, sensitivity and reproducibility while preventing oxidative damage with this low-bleed, polar GC column.
Max. Temperature | 240/250°C |
---|---|
Stationary Phase | TraceGOLD™ TG-WAXMS A |
Polarity | Polar |
USP Type | G25, G35 |
Analyze FAMEs with excellent thermal stability using this column.
Max. Temperature | 240/260°C |
---|---|
Stationary Phase | TraceGOLD™ TG-WAXMS |
Polarity | Polar |
USP Type | G14, G15, G16, G20, G39 |
Utilizes a chemically altered tubing surface to reduce peak tailing and eliminates the need for column priming when analysing amines and other basic compounds.
Max. Temperature | 220°C |
---|---|
Stationary Phase | TraceGOLD™ TG-35 MS Amine |
Polarity | Mid-Polar |
For Use With (Application) | GC/MS Amines Including Alkylamines, Diamines, Triamines and Ethanolamines,GC/MS for Nitrogen-Containing Heterocyclics |
Thermo Scientific™ TraceGOLD TG-5HT GC Columns offer extended operation up to 400°C, ideal for high temperature GC applications.
Max. Temperature | 380/400°C |
---|---|
Stationary Phase | TraceGOLD™ TG-5 HT |
Polarity | Low-Polar |
For Use With (Application) | Pesticides Analysis,GC/MS for Pesticides,GC/MS for Residual Solvents, Solvents, and Solvent Impurities |
USP Type | G27, G36 |
Product Line | TraceGOLD |
Use Thermo Scientific™ TracePLOT™ TG-BOND Alumina GC Columns for linear and quantitative analysis of polar unsaturated hydrocarbons.
Stationary Phase | TracePLOT™ TG-BOND Alumina |
---|
Analyze organophosphorus pesticides with ultra-low bleed, superior inertness and consistent reproducibility.
Max. Temperature | 330°C |
---|---|
Length (Metric) | 30 m |
Polarity | Non-Polar |
For Use With (Application) | GC/MS for Organophosphorus Pesticides |
Max. Temperature | 320°C |
---|---|
Type | GC Capillary Column |
Stationary Phase | TraceGOLD™ TG-BIODIESELMT |
Diameter (Metric) Inner | 0.32 mm |
Quantity | Each |
Polarity | Non-Polar |
Film Thickness | 0.1 μm |
Product Line | TraceGOLD |
Push the limits of your analyses with these nonpolar, metal columns designed for elevated temperature use.
Max. Temperature | Up to 430°C |
---|---|
Polarity | Non-Polar |
Produce consistent results with this low-bleed, stable column produces.
Particle Size | 0.25 μm |
---|---|
Temperature Range | 40°C°C to 260°C |
For Use With (Application) | GC/MS |
USP Type | G14, G15, G16, G20, G39 |
Thermo Scientific™ TraceGOLD TG-5MS AMINE GC Column enables analysis of ppm levels of amines without column priming.
Max. Temperature | 300/315°C |
---|---|
Stationary Phase | TraceGOLD™ TG-5 MS Amine |
Polarity | Low-Polar |
For Use With (Application) | GC/MS for Analysis of Amines and Other Basic Compounds, Including Alkylamines, Diamines, Triamines, and Ethanolamines,GC/MS for Nitrogen-Containing Heterocyclics |
Optimize separation when analyzing active environmental compounds with this low-bleed GC column with superior inertness.
Resolve compounds that phenyl and cyano phases cannot using a low-bleed GC column with an exceptionally inert phase.
Max. Temperature | 320/340°C |
---|---|
Stationary Phase | TraceGOLD™ TG-200 MS |
Polarity | Mid-Polar |
USP Type | G6 |