Promotional price valid on web orders only. Your contract pricing may differ. Interested in signing up for a dedicated account number?
Learn More

Thermo Scientific™ TraceGOLD TG-1MT Metal GC Columns

Push the limits of your analyses with these nonpolar, metal columns designed for elevated temperature use.

$529.00 - $1018.00

Specifications

Max. Temperature Up to 430°C
Polarity Non-Polar
View More Specs

Products 16
Catalog Number Mfr. No. Length (Metric) Diameter (Metric) Inner For Use With (Application) Film Thickness Price Quantity & Availability  
Catalog Number Mfr. No. Length (Metric) Diameter (Metric) Inner For Use With (Application) Film Thickness Price Quantity & Availability  
26-M99-4120
View Documents
Thermo Scientific™
26M994120
5 m 0.53 mm Hydrocarbons Anaylsis, GC for Hydrocarbons, GC for Gasoline Range Organics (GROs), GC for Drugs of Abuse, GC for PCBs 0.88 μm
Each for $721.50
Add to Cart
 
26-M99-4130
View Documents
Thermo Scientific™
26M994130
5 m 0.53 mm Hydrocarbons Anaylsis, GC for Hydrocarbons, GC for Gasoline Range Organics (GROs), GC for Drugs of Abuse, GC for PCBs 0.1 μm
Each for $688.50
Add to Cart
 
03-341-976
View Documents
Thermo Scientific™
26M993480
10 m 0.53 mm Hydrocarbons Anaylsis, GC/MS for Hydrocarbons, GC/MS for Gasoline Range Organics (GROs), GC/MS for Drugs of Abuse, GC/MS for PCBs 2.65 μm
Each for $529.00
Add to Cart
 
03-155-002
View Documents
Thermo Scientific™
26M991420
30 m 0.25 mm Hydrocarbons Anaylsis, GC for Hydrocarbons, GC for Gasoline Range Organics (GROs), GC for Drugs of Abuse, GC for PCBs 0.25 μm
Each for $1,018.00
Add to Cart
 
03-155-001
View Documents
Thermo Scientific™
26M991300
15 m 0.25 mm PCBs Analysis, GC for Hydrocarbons, GC for Gasoline Range Organics (GROs), GC for Drugs of Abuse, GC for PCBs 0.25 μm
Each for $572.50
Add to Cart
 
03-155-005
View Documents
Thermo Scientific™
26M991540
60 m 0.25 mm GC for Optimal Signal-to-Noise Ratio, Sensitivity, and MS Integrity, GC for Hydrocarbons, GC for Gasoline Range Organics (GROs), GC for Drugs of Abuse, GC for PCBs 25 μm Item Discontinued This item has been discontinued by the supplier. Please to view product availability in your area. N/A
26-053-0480
View Documents
Thermo Scientific™
260530480
15 m 0.32 mm GC for Optimal Signal-to-Noise Ratio, Sensitivity, and MS Integrity, GC for Hydrocarbons, GC for Gasoline Range Organics (GROs), GC for Drugs of Abuse, GC for PCBs 0.1 μm Item Discontinued This item has been discontinued by the supplier. Please to view product availability in your area. N/A
03-155-012
View Documents
Thermo Scientific™
26M993360
30 m 0.53 mm GC for Optimal Signal-to-Noise Ratio, Sensitivity, and MS Integrity, GC for Hydrocarbons, GC for Gasoline Range Organics (GROs), GC for Drugs of Abuse, GC for PCBs 1.5 μm Item Discontinued This item has been discontinued by the supplier. Please to view product availability in your area. N/A
03-155-011
View Documents
Thermo Scientific™
26M992980
30 m 0.53 mm GC for Optimal Signal-to-Noise Ratio, Sensitivity, and MS Integrity, GC for Hydrocarbons, GC for Gasoline Range Organics (GROs), GC for Drugs of Abuse, GC for PCBs 1 μm Item Discontinued This item has been discontinued by the supplier. Please to view product availability in your area. N/A
03-155-004
View Documents
Thermo Scientific™
26M992960
30 m 0.25 mm GC for Optimal Signal-to-Noise Ratio, Sensitivity, and MS Integrity, GC for Hydrocarbons, GC for Gasoline Range Organics (GROs), GC for Drugs of Abuse, GC for PCBs 1 μm Item Discontinued This item has been discontinued by the supplier. Please to view product availability in your area. N/A
03-155-010
View Documents
Thermo Scientific™
26M992250
30 m 0.53 mm GC for Optimal Signal-to-Noise Ratio, Sensitivity, and MS Integrity, GC for Hydrocarbons, GC for Gasoline Range Organics (GROs), GC for Drugs of Abuse, GC for PCBs 0.5 μm Item Discontinued This item has been discontinued by the supplier. Please to view product availability in your area. N/A
03-155-008
View Documents
Thermo Scientific™
26M992860
15 m 0.53 mm GC for Optimal Signal-to-Noise Ratio, Sensitivity, and MS Integrity, GC for Hydrocarbons, GC for Gasoline Range Organics (GROs), GC for Drugs of Abuse, GC for PCBs 1 μm Item Discontinued This item has been discontinued by the supplier. Please to view product availability in your area. N/A
03-155-009
View Documents
Thermo Scientific™
26M991440
30 m 0.53 mm GC for Optimal Signal-to-Noise Ratio, Sensitivity, and MS Integrity, GC for Hydrocarbons, GC for Gasoline Range Organics (GROs), GC for Drugs of Abuse, GC for PCBs 0.25 μm Item Discontinued This item has been discontinued by the supplier. Please to view product availability in your area. N/A
03-155-006
View Documents
Thermo Scientific™
26M992130
15 m 0.53 mm GC for Optimal Signal-to-Noise Ratio, Sensitivity, and MS Integrity, GC for Hydrocarbons, GC for Gasoline Range Organics (GROs), GC for Drugs of Abuse, GC for PCBs 0.5 μm Item Discontinued This item has been discontinued by the supplier. Please to view product availability in your area. N/A
03-155-003
View Documents
Thermo Scientific™
26M992230
30 m 0.25 mm GC for Optimal Signal-to-Noise Ratio, Sensitivity, and MS Integrity, GC for Hydrocarbons, GC for Gasoline Range Organics (GROs), GC for Drugs of Abuse, GC for PCBs 0.5 μm Item Discontinued This item has been discontinued by the supplier. Please to view product availability in your area. N/A
03-155-013
View Documents
Thermo Scientific™
26M993960
30 m 0.53 mm GC for Optimal Signal-to-Noise Ratio, Sensitivity, and MS Integrity, GC for Hydrocarbons, GC for Gasoline Range Organics (GROs), GC for Drugs of Abuse, GC for PCBs 3 μm Item Discontinued This item has been discontinued by the supplier. Please to view product availability in your area. N/A
Description

Description

Push the limits of your analyses with Thermo Scientific™ TraceGOLD™ TG-1MT GC Columns. These nonpolar, metal columns allow you to work a temperatures up to 430°C with no compromise in performance when analyzing highly active and aggressive compounds.

Engineered for Superior Performance:
  • Nonpolar, 100% dimethyl polysiloxane
  • Low bleed for excellent signal-to-noise ratio, sensitivity and mass spectral integrity
  • Stable to 430°C
Applications:
  • Hydrocarbons
  • Solvent impurities
  • Polychlorinated biphenyl (PCB) congeners
  • Aroclor mixes
  • Simulated distillation
  • Drugs of abuse
  • Natural gas odorants
  • Essential oils
  • Pesticides
A Leap Forward in Performance with Low Bleed and Superior Inertness:
  • A low bleed, stable column produces consistent results.
  • Low baseline noise enables improved limits of detection with enhanced resolution of low level analytes. Minimizing column bleed extends the column lifetime, leading to higher productivity.
  • Reducing column bleed increases reproducibility of the stationary phase over time, resulting in greater run-to-run and batch-to-batch reproducibility.
  • Superior inertness ensures excellent peak shape and sensitivity, especially for highly active or difficult compounds.
Recommended For:
  • Hydrocarbons
  • Gasoline range organics (GROs)
  • Drugs of abuse
  • PCBs
Alternative Uses:
  • Chlorinated aromatics
  • Organochlorine pesticides
  • Organophosphorous pesticides
  • Polycyclic aromatic hydrocarbons (PAHs)
  • Paraffins
  • Polywax
  • Pyrethroids
  • Semivolatiles
  • Xylenes
Similar To:
  • MXT™-1
  • DB-1
  • DB-1MS
  • HP-1
  • HP-1MS
  • Ultra-1
  • SPB™-1
  • Equity™-1
  • MDN-1
  • CP-Sil 5 CB
  • VF-1ms
  • ZB-1HT
Specifications

Specifications

Up to 430°C
Non-Polar
SDS
Documents

Documents

Product Certifications

Limited warranty period: Subject to all warranty requirements and exclusions set out in our Terms and Conditions of Sale, this product is warranted from the date we ship the product and for ninety (90) days thereafter. Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.

Provide Content Correction

We continue to work to improve your shopping experience and your feedback regarding this content is very important to us. Please use the form below to provide feedback related to the content on this product.

Product Title

By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.

Cancel Submit