Test
Para 12 Plus is a whole blood hematology control formulated for the Abbott™ CELL-DYN five-part differential Ruby™ instrument. It features vials with pierceable caps for autosampling and is available in low, normal and high levels.
Type | Para 12™ plus Whole Blood Control |
---|---|
Content And Storage | 2°C to 10°C |
Stability | 75 Days |
Format | Vial |
For Use With (Equipment) | Abbott CELL-DYN™ 3200, 3500, and 3700 |
Certifications/Compliance | CE |
Intended Use | For evaluating the accuracy and precision of hematology instruments that provide a WBC differential |
Source | Stabilized Human or Mammalian RBC, Mammalian or Simulated White Blood Cells and a Platelet Component |
Para 4 is a hematology control for laboratories that perform a limited number of hematology tests utilizing manual or semi-manual methods. It is available in low, normal and high levels.
Type | Para 4™ Four Parameter Hematology Control |
---|---|
Content And Storage | 2°C to 10°C |
Stability | 110 Days |
Assay Target | WBC, RBC, Hgb, Hct and Platelet |
For Use With (Equipment) | HemoCue™ B-Hemoglobin photometer and Hb201+, ITC Hgb Pro professional hemoglobin testing system |
Certifications/Compliance | CE |
Intended Use | For small laboratories performing a limited number of hematology tests |
STaK-Chex Plus Retics is a comprehensive, whole blood five-part white cell differential control with reticulocytes and nucleated red blood cells for use on Beckman Coulter™ instruments. It features vials with pierceable caps for autosampling and is available in low, normal and high levels.
Type | STaK-Chex™ plus Retics Control |
---|---|
Content And Storage | 2°C to 10°C |
Stability | 105 Days |
For Use With (Equipment) | Beckman Coulter™ UniCel™ DxH™ 800, LH780/785, LH 750/755, LH500 and HmX |
Intended Use | For evaluating the accuracy and precision of automated procedures that measure Blood cell parameters |
Customized HemoScreen Quality Control Kit used to evaluate system accuracy and precision.
Quality control material for periodic control of HemoCue B-Glucose and HemoCue Glucose 201 analyzers
Type | Tri Level Control |
---|---|
For Use With (Equipment) | ABX Micros 60 and ABX Micros CRP or CRP 200 |
Quantity | Each |
For use in verification of precision/accuracy for HemoCue Albumin 201 system
Includes | Dropper tip and colored screw cap |
---|---|
Type | AlbuTrol™ Albumin Control |
Content And Storage | 2°C to 8°C |
Stability | 1 Month |
For Use With (Equipment) | HemoCue™ Albumin 201 |
Color | Clear |
Quantity | 2 x 1 mL |
Shelf Life | 15 Months |
Intended Use | For use in verification of precision/accuracy |
Source | Human Urine Containing Albumin |
Retic-Chex II is a tri-level whole blood control with reticulocytes used to verify the accuracy and precision of manual reticulocyte counting methods.
Type | Hematology II Controls |
---|
CD-Chex CD117 Plus is a flow cytometry control that provides assay values for CD117, CD25 and CD71 on abnormal and total leukocytes.
Type | CD-Chex™ CD117 Plus Cytometry Control |
---|---|
Content And Storage | 2°C to 10°C |
Stability | 30 Days Open, 90 Days Closed |
Form | Liquid |
For Use With (Equipment) | BD Biosciences and Beckman Coulter™ flow cytometry system |
For Use With (Application) | Positive procedural control for CD117, CD25 and CD71, to monitor reagent staining, erythrocyte lysis, sample preparation, and instrument performance, eliminates the need for labs to hold and validate patient samples |
With A1c-Cellular, you can evaluate the entire HbA1c analysis process, from instrument to reagents, to ensure accurate patient results.
Type | A1c-cellular™ Clinical Control |
---|---|
Content And Storage | 2°C to 8°C |
Stability | 180 Days |
Format | Cap-pierceable Plastic Vial |
For Use With (Equipment) | Abbott Architect™ c system, Menarini ADAMS™ A1c HA-8160, Beckman Coulter™ UniCel™ DxC 600/800, Bio-rad™ D-10/Variant II™/Variant II™ |
Level | 1, 2 |
Certifications/Compliance | CE |
Intended Use | For evaluating the accuracy and precision of HbA1c procedures |
Source | Human RBC |
Ideal for use with HemataSTAT™ and other microhematocrit centrifuges
Type | HemataCHEK™ Hematology Reference Control |
---|---|
Content And Storage | 40°C to 80°C |
Stability | 31 Days Open Vial |
Format | Vial |
For Use With (Equipment) | Microhematocrit centrifuge |
Quantity | 6 Pack |
Shelf Life | 2 Years |
Intended Use | For monitoring the Hematocrit determination |
Source | Human Blood |
For Use With (Equipment) | HemoCue™ 201 DM analyzer |
---|---|
Quantity | Each |
For use with HemoPoint H2™ DMS Hemoglobin Analyzer
For use with HemoPoint H2™ DMS Hemoglobin Analyzer