Promotional price valid on web orders only. Your contract pricing may differ. Interested in signing up for a dedicated account number?
Learn More

Labconco™ Protector™ Controlled Atmosphere Glove Boxes
SDP

Glove boxes provide a leak-tight environment for work with contamination-sensitive materials

Supplier:  Labconco™ 5080031

Request Bulk Order

 View more versions of this product

Catalog No. 16-200-432


Add to Cart

Alert:

This item is a non-standard voltage; please ensure you are ordering the correct product. Please contact customer service for assistance: 1-800-766-7000.


Requires : Supporting base, vacuum pump for evacuating, inert gas for filling.

Description

Description

Key Features

  • Exceed Class 1 atmosphere containment conditions for oxygen permeation <1.67 ppm/min. per ISO 10648-2 test method
  • Four manual valves with 3/8 in. compression fittings—two on the main chamber and two on the transfer chamber
  • Automatic control of the main chamber pressure, main chamber evacuation and filling cycles, and transfer chamber evacuation and filling cycles
  • Regulation of vacuum/pressure between -5 and +5 inches of water gauge in the main chamber and between 0 and -29.5 inches of mercury in the transfer chamber
  • Mutable, audible/visual alarm that sounds when pressure/vacuum level is outside set limits
  • Three-position foot pedal (increase gas/fill, off, evacuate/decrease gas)
  • Factory-installed, rear-mounted, low profile stainless steel pressure relief bubbler at ±6 inches of water gauge
  • Two rear-mounted inlet and outlet 3/4 in. OD compression fittings for easy connection to optional gas purifier or accessory drying train
  • Factory leak-tested—no detectable leaks greater than 1 × 10-6mL/sec.

Additional Features

  • LCD display of main chamber and transfer chamber pressure in inches of water, inches of mercury and mBar
  • 0.38 in. thick laminated safety glass viewing window with 36.0W × 27.6 in.H (91 × 70cm) viewing area
  • Pair of neoprene gloves 0.015 in. thick, 30 in. long, size 9 3/4
  • Two 8 in. ID epoxy-coated aluminum, double-grooved glove ports with neoprene gaskets
  • Switches for light and electrical receptacle
  • Two 25-watt fluorescent lights
  • Dry-powder epoxy-coated, 18 and 20 gauge steel exterior panels

Stainless Steel-lined Model Features

  • Type 304 stainless steel liner with Type 304 stainless steel inner and outer transfer chamber doors; Type 304 stainless steel front panel
  • Performance tested to maintain oxygen levels as low as 0.2 ppm and moisture levels as low as 1 ppm
  • Oxygen permeation <0.16 ppm/min per ISO 10648-2
Fiberglass-lined Model Features
  • One-piece molded fiberglass liner with clear acrylic inner and outer transfer chamber doors
  • Performance tested to maintain oxygen levels as low as 0.4 ppm and moisture levels as low as 2 ppm
  • Oxygen permeation <0.3 ppm/min per ISO 10648-2

Certifications

ETL listed, UL 61010-1 and CAN/CSA C22.2 No. 1010.1 conformity (North American models); CE marked (International models)

Warranty and Services

One year warranty on parts and labor.

Specifications

Specifications

Glove Box
Fiberglass
CE
87.4 cm
Controlled atmosphere sensitive materials
45.7 in.
UK Plug
208/230 V
500 lb.
63.9 in.
162.3 cm
Fluorescent (2 x 25 W)
10 A
34.4 in.
LCD
AtmosPure™ Re-Gen gas purifier
116.1 cm
2
1 Year
227 kg
35 in.
88.9 cm
Product Suggestions

Product Suggestions

Safety and Handling

Safety and Handling

WARNING: Cancer - www.P65Warnings.ca.gov
SDS
Documents

Documents

Product Certifications
Promotions

Promotions

Provide Content Correction

We continue to work to improve your shopping experience and your feedback regarding this content is very important to us. Please use the form below to provide feedback related to the content on this product.

Product Title

By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.

Cancel Submit