Thermo Scientific™ Acclaim™ 120 C18 Columns
Use these high-efficiency reversed phase C18 columns for maximum resolution in a wide variety of applications.
Pore Size | 120 Å |
---|---|
Carbon Load | 18% |
Stationary Phase | C18 |
Temperature | 60°C |
Endcapped | Yes |
Column Type | Reversed Phase |
pH | 2 to 8 |
Surface Area | 300 m²/g |
USP Type | L1 |
Thermo Scientific™ Acclaim™ Mixed Mode WCX-1 HPLC Columns
Separate cationic molecules with powerful adjustable selectivity control using this mixed-mode reversed-phase and weak cation-exchange LC column.
Pore Size | 120 Å |
---|---|
Stationary Phase | Hydrophobic Alkyl Chain with a Carboxyl Terminus |
Temperature | 50°C |
Phase | Reversed Phase, Ion Exchange, Ion Exclusion, HILIC |
Endcapped | Proprietary |
Column Type | Mixed Mode |
Surface Area | 300 m²/g |
Product Line | Acclaim |
USP Type | L85 |
Thermo Scientific™ Acclaim™ Surfactant Plus HPLC Columns
Use for simultaneous separation of anionic, nonionic, cationic, and amphoteric surfactants with CAD and LC-MS detection.
Pore Size | 120 Å |
---|---|
Stationary Phase | Proprietary |
Temperature | 50°C |
Endcapped | Yes |
Packing Material | Spherical, Fully Porous, Ultrapure Silica |
Column Type | Specialty/Application Specific |
pH | 2.5 to 7.5 |
Surface Area | 300 m²/g |
Product Line | Acclaim |
Thermo Scientific™ Acclaim™ Explosives E2 HPLC Columns
Use for baseline resolution of all 14 explosives listed in EPA Method 531.2.
Pore Size | 120 Å |
---|---|
Stationary Phase | Proprietary |
Temperature | 50°C |
Phase | Reversed Phase |
For Use With | LC/MS |
Endcapped | Yes |
Column Type | Specialty/Application Specific |
pH | 2.5 to 7.5 |
Surface Area | 300 m²/g |
Product Line | Acclaim |
Thermo Scientific™ Acclaim™ SEC-300 Size Exclusion Chromatography HPLC Columns
Separate water-soluble polymers and oligomers with the Acclaim family of resin-based, high-performance, size-exclusion chromatography columns.
Pore Size | 300 Å |
---|---|
Particle Size | 5 μm |
Stationary Phase | Proprietary |
Temperature | 60°C |
Phase | Size Exclusion |
Endcapped | Yes |
Column Type | Size Exclusion |
pH | 2 to 12 |
Technique | Bio-LC |
Particle Shape | Spherical |
Product Line | Acclaim |
USP Type | N/A |
Thermo Scientific™ Acclaim™ Polar Advantage II HPLC Columns
Resolve polar and nonpolar compounds in a single run. These columns have high pH stability (pH 1.5–10) in the separation of basic, neutral, and acidic species.
Pore Size | 120 Å |
---|---|
Stationary Phase | Polar Embedded |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Packing Material | Spherical, Fully Porous, Ultrapure Silica |
Column Type | Reversed Phase |
Surface Area | 300 m²/g |
USP Type | L60 |
Thermo Scientific™ Acclaim™ Mixed Mode WAX-1 HPLC Columns
When you need powerful selectivity control for the separation of anionic molecules, use Thermo Scientific™ Acclaim™ Mixed-Mode WAX-1 LC columns.
Pore Size | 120 Å |
---|---|
Phase | Reversed Phase, Ion Exchange, HILIC |
Column Type | Mixed Mode |
pH | 2.5 to 7.5 |
Surface Area | 300 m²/g |
Product Line | Acclaim |
USP Type | L78 |
Thermo Scientific™ Acclaim™ Carbonyl C18 HPLC Columns
Use for superior resolution and high-throughput separation of carbonyls, dinitrophenylhydrazine (DNPH) derivatives of aldehydes and ketones.
Pore Size | 120 Å |
---|---|
Temperature | 50°C |
Phase | Reversed Phase |
Endcapped | Yes |
pH | 2.5 to 7.5 |
Surface Area | 300 m²/g |
Thermo Scientific™ Acclaim™ Polar Advantage HPLC Columns
Use for reversed-phase separation of basic or pharmaceutical compounds using highly aqueous mobile phases.
Pore Size | 120 Å |
---|---|
Carbon Load | 17% |
Stationary Phase | Polar Embedded |
Temperature | 60°C |
Endcapped | Yes |
Column Type | Reversed Phase |
pH | 2 to 8 |
Surface Area | 300 m²/g |
USP Type | L60 |
Thermo Scientific™ Acclaim™ Trinity P1 HPLC Columns
Use these mixed-mode columns for simultaneous separation of pharmaceutical drug substances and their counter ions with high efficiency.
Pore Size | 300 Å |
---|---|
Particle Size | 3 μm |
Stationary Phase | Reversed Phase/Anion Exchange/Cation Exchange |
Temperature | 45°C |
Phase | Reversed Phase and Ion Exchange |
Endcapped | Proprietary |
Column Type | Mixed Mode |
pH | 2.5 to 7 |
Surface Area | 100 m²/g |
Max. Pressure | 4500 psi (310 bar) |
Product Line | Acclaim |
Thermo Scientific™ Acclaim™ Mixed Mode HILIC-1 HPLC Columns
Get all the advantages of reversed-phase and hydrophilic interaction liquid chromatography (HILIC) in one column with the Thermo Scientific™ Acclaim™ Mixed-Mode HILIC-1 column.
Pore Size | 120 Å |
---|---|
Stationary Phase | Hydrophobic Alkyl Chain with a Diol Group |
Temperature | 50°C |
Phase | Reversed Phase and HILIC |
Endcapped | Proprietary |
Column Type | Mixed Mode |
pH | 2.5 to 7.5 |
Surface Area | 300 m²/g |
Product Line | Acclaim |
USP Type | N/A |
Thermo Scientific™ Acclaim™ Organic Acid HPLC Columns
Use for separation of hydrophilic, aliphatic, and aromatic organic acids.
Pore Size | 120 Å |
---|---|
Carbon Load | 17% |
Stationary Phase | Proprietary |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Specialty/Application Specific |
pH | 2 to 8 |
Surface Area | 300 m²/g |
Product Line | Acclaim |
Thermo Scientific™ Acclaim™ Surfactant HPLC Columns
Use for outstanding separation of anionic, nonionic, and cationic surfactants with ELSD and RI detectors.
Pore Size | 120 Å |
---|---|
Carbon Load | 12% |
Stationary Phase | Proprietary |
Temperature | 60°C |
Endcapped | Yes |
Column Type | Specialty/Application Specific |
pH | 2.5 to 7.5 |
Surface Area | 300 m²/g |
Product Line | Acclaim |
Thermo Scientific™ Acclaim™ HILIC-10 HPLC Columns
Use this HILIC column to retain and separate highly polar molecules that are unretained by reversed-phase chromatography.
Pore Size | 120 Å |
---|---|
Carbon Load | 8% |
Stationary Phase | Proprietary |
Temperature | 70°C |
Phase | HILIC |
For Use With | LC/MS |
Endcapped | Yes |
Column Type | HILIC |
pH | 2 to 8 |
Surface Area | 300 m²/g |
Product Line | Acclaim |
Thermo Scientific™ Acclaim™ Carbamate HPLC Columns
Achieve baseline separation of carbamate specified in U.S. EPA Method 531.2 with high-efficiency Thermo Scientific™ Acclaim™ Carbamate LC Columns.
Pore Size | 120 Å |
---|---|
Stationary Phase | Proprietary |
Temperature | 60°C |
Endcapped | Yes |
Column Type | Specialty/Application Specific |
pH | 3 to 7 |
Surface Area | 300 m²/g |
Product Line | Acclaim |