Chromatography Columns and Cartridges
Chromatography Columns and Cartridges
Filtered Search Results
Thermo Scientific™ Accucore™ C18 HPLC Columns
Use this column, with its specially designed solid core, for a broad range of nonpolar analytes across multiple applications.
Pore Size | 80 Å |
---|---|
Particle Size | 2.6 μm |
Carbon Load | 9% |
Stationary Phase | C18 |
Temperature | 70°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
pH | 1 to 11 |
Surface Area | 130 m²/g |
Particle Shape | Spherical Solid Core |
USP Type | L1 |
Thermo Scientific™ Accucore™ 150-C4 HPLC Columns
Use this specially designed solid core column with a C4 functionality for biomolecules that bind too tightly to C8 or C18 columns.
Pore Size | 150 Å |
---|---|
Particle Size | 2.6 μm |
Carbon Load | 2% |
Stationary Phase | C4 |
Temperature | 60°C |
Phase | Reversed Phase |
For Use With | HPLC |
Endcapped | Yes |
Packing Material | Spherical, Solid Core, Ultrapure Silica |
Column Type | Reversed Phase |
pH | 2 to 9 |
Surface Area | 80 m²/g |
USP Type | L26 |
Thermo Scientific™ Accucore™ XL C18 HPLC Columns
Use these solid core columns for optimal retention of a broad range of nonpolar analytes across multiple applications.
Pore Size | 80 Å |
---|---|
Particle Size | 4 μm |
Carbon Load | 7% |
Stationary Phase | C18 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
pH | 1 to 11 |
Surface Area | 130 m²/g |
Max. Pressure | 8700 psi (600 bar) |
Product Line | Accucore |
USP Type | L1 |
Thermo Scientific™ Accucore™ 150 Amide HILIC HPLC Columns
Designed for the separation of hydrophilic biomolecules in HILIC mode—an excellent choice for glycan separations.
Thermo Scientific™ Accucore™ PFP HPLC Columns
Use these solid core particle columns to analyze difficult-to-resolve mixtures including DOA and pharmaceuticals.
Pore Size | 80 Å |
---|---|
Stationary Phase | PFP (Pentafluorophenylpropyl) |
Temperature | 70°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
Surface Area | 130 m²/g |
Max. Pressure | 14500 psi (1000 bar) |
Particle Size | 2.6 μm |
Carbon Load | 5% |
Packing Material | Spherical, Solid Core, Ultrapure Silica |
pH | 2 to 8 |
Product Line | Accucore |
USP Type | L43 |
Thermo Scientific™ Accucore™ Vanquish™ C18+ UHPLC Columns, 1.5μm
Use the 1.5μm solid core particles of these columns with the Vanquish UHPLC system for unique high-efficiency, high-resolution analyses.
Pore Size | 80 Å |
---|---|
Particle Size | 1.5 μm |
Carbon Load | 6.5% |
Stationary Phase | C18 |
Temperature | 70°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
Diameter (Metric) | 2.1 mm |
pH | 2 to 9 |
Surface Area | 110 m²/g |
USP Type | L1 |
Thermo Scientific™ Accucore™ Polar Premium HPLC Columns
Use this specially designed solid core column for fast high resolution with high pH stability for separation of basic, neutral, and acidic species.
Pore Size | 150 Å |
---|---|
Temperature | 70°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
Surface Area | 90 m²/g |
Max. Pressure | 14500 psi (1000 bar) |
Particle Size | 2.6 μm |
Carbon Load | 9% |
Packing Material | Spherical, Solid Core, Ultrapure Silica |
pH | 1.5 to 10.5 |
Particle Shape | Spherical Solid-core |
Product Line | Accucore |
USP Type | L60 |
Thermo Scientific™ Accucore™ HILIC HPLC Columns
Offer enhanced retention of polar and hydrophilic analytes with Thermo Scientific™ Accucore™ HILIC LC Columns.
Pore Size | 80 Å |
---|---|
Particle Size | 2.6 μm |
Stationary Phase | Silica |
Temperature | 70°C |
Phase | Normal Phase and HILIC |
Packing Material | Spherical, Solid Core, Ultrapure Silica |
Column Type | Mixed Mode |
pH | 2 to 8 |
Surface Area | 130 m²/g |
Particle Shape | Spherical Solid Core |
Max. Pressure | 14500 psi (1000 bar) |
Product Line | Accucore |
USP Type | L3 |
Thermo Scientific™ Accucore™ aQ C18 Polar Endcapped HPLC Columns
Use this column, with its specially designed solid core, for the separation of compounds in highly aqueous mobile phases.
Pore Size | 80 Å |
---|---|
Stationary Phase | C18 |
Temperature | 70°C |
Phase | Reversed Phase |
Endcapped | Polar |
Column Type | Reversed Phase |
Surface Area | 130 m²/g |
Max. Pressure | 14500 psi (1000 bar) |
Particle Size | 2.6 μm |
Carbon Load | 9% |
Packing Material | Spherical, Solid Core, Ultrapure Silica |
pH | 2 to 9 |
Particle Shape | Spherical Solid Core |
Product Line | Accucore |
USP Type | L1 |
Thermo Scientific™ Accucore™ Phenyl-Hexyl HPLC Columns
Use this solid core column for fast, high-resolution separations of aromatic and moderately polar compounds.
Pore Size | 80 Å |
---|---|
Temperature | 70°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
Surface Area | 130 m²/g |
Max. Pressure | 14500 psi (1000 bar) |
Particle Size | 2.6 μm |
Carbon Load | 5% |
Packing Material | Spherical, Solid Core, Ultrapure Silica |
pH | 2 to 8 |
Particle Shape | Spherical Solid Core |
Product Line | Accucore |
USP Type | L11 |
Thermo Scientific™ Accucore™ Narrow Selectivity Kits
Verify optimum selectivity of Thermo Scientific™ Accucore™ HPLC columns over a narrow range.
Pore Size | 80 Å |
---|---|
Particle Size | 2.6 μm |
Stationary Phase | aQ C18, C18, RP-MS |
For Use With | HPLC |
Endcapped | Yes |
Diameter (Metric) | 2.1 mm |
Surface Area | 130 m²/g |
Particle Shape | Spherical Solid Core |
Column Format | HPLC Column Kit |
Thermo Scientific™ Accucore™ Polar Selectivity Kits
Verify optimum selectivity of Thermo Scientific™ Accucore™ HPLC columns for polar analytes.
Pore Size | 80 Å |
---|---|
Particle Size | 2.6 μm |
Stationary Phase | aQ C18, HILIC, PFP |
For Use With | HPLC |
Endcapped | Yes |
Packing Material | Silica |
Diameter (Metric) | 2.1 mm |
Surface Area | 130 m²/g |
Particle Shape | Spherical Solid Core |
Column Format | HPLC Column Kit |
Thermo Scientific™ Accucore™ XL C8 HPLC Columns
Improve laboratory productivity using Thermo Scientific™ Accucore™ XL C8 Columns.
Pore Size | 80 Å |
---|---|
Particle Size | 4 μm |
Carbon Load | 4% |
Stationary Phase | C8 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
pH | 2 to 9 |
Surface Area | 130 m²/g |
Max. Pressure | 8700 psi (600 bar) |
USP Type | L7 |
Thermo Scientific™ Accucore™ Urea HILIC HPLC Columns
Offer unique HILIC selectivity and low ion exchange activity with Thermo Scientific™ Accucore™ Urea HILIC LC Columns.
Pore Size | 80 Å |
---|---|
Particle Size | 2.6 μm |
Stationary Phase | Urea-HILIC |
Temperature | 70°C |
Phase | HILIC |
Packing Material | Spherical, Solid Core, Ultrapure Silica |
Column Type | HILIC |
pH | 2 to 8 |
Surface Area | 130 m²/g |
Particle Shape | Spherical Solid-core |
Max. Pressure | 14500 psi (1000 bar) |
USP Type | N/A |
Thermo Scientific™ Accucore™ Phenyl-X HPLC Columns
Use this solid core column for fast, high-resolution separations of aromatic compounds.
Pore Size | 80 Å |
---|---|
Particle Size | 2.6 μm |
Carbon Load | 6% |
Temperature | 70°C |
Phase | Reversed Phase |
Endcapped | Yes |
Packing Material | Spherical, Solid Core, Ultrapure Silica |
Column Type | Reversed Phase |
pH | 2 to 8 |
Surface Area | 130 m²/g |
Max. Pressure | 14500 psi (1000 bar) |
USP Type | N/A |