Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - FID Only (No Probes)

Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.

$14261.00 - $19807.00

Specifications

Accuracy ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm
Battery Life 10 hours at 0°C
Battery Type Lithium Ion
Certifications/Compliance USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb
Computer Requirements USB port, Windows XP operating system or higher
View More Specs

Products 6
Catalog Number Mfr. No. Includes Outputs Price Quantity & Availability  
Catalog Number Mfr. No. Includes Outputs Price Quantity & Availability  
50-227-1731
View Documents
Thermo Scientific™
2020A3N2N2
Analyzer Bluetooth
Each for $17,906.00
Add to Cart
 
50-227-1733
View Documents
Thermo Scientific™
2020A3N3N2
Analyzer GPS
Each for $14,997.00
Add to Cart
 
50-227-1728
View Documents
Thermo Scientific™
2020A3N1N2
Analyzer None
Each for $14,261.00
Add to Cart
 
50-227-1730
View Documents
Thermo Scientific™
2020A3N2C2
Analyzer with Transportation Case Bluetooth
Each for $19,033.00
Add to Cart
 
50-227-1732
View Documents
Thermo Scientific™
2020A3N2R2
Analyzer with Hydrogen Refill Assembly Bluetooth
Each for $18,705.00
Add to Cart
 
50-227-1729
View Documents
Thermo Scientific™
2020A3N2B2
Analyzer with Case and Refill Assembly Bluetooth
Each for $19,807.00
Add to Cart
 
Description

Description

Quickly detect fugitive emissions of organic and inorganic compounds for Method 21 compliance, LDAR applications and site remediation with this lightweight, intrinsically safe portable gas leak detector. The Thermo Scientific™ TVA2020 Toxic Vapor Analyzer can be configured as an FID analyzer (flame ionization detector) or dual detection FID analyzer and PID analyzer (photo ionization detector). Key features include reduced response times, increased user-serviceability, and Bluetooth™ connectivity.

Easy-to-Own and Operate

The TVA2020 Toxic Vapor Analyzer is 21% lighter than earlier models and more compact than most stand alone FID analyzers. The lightweight and compact design reduces fatigue for true portability and is easier to service in the field. In addition, a variety of options are available such as a basic or enhanced probe, carrying case, and hydrogen refill assembly.

Optional Bluetooth communication transmits concentration data to a handheld device containing the LDAR software database thereby eliminating the need to transfer files post-monitoring and provide a greater access to route information.

The Technology You Expect

Detect gas leaks from refineries and chemical plants to comply with U.S. EPA Method 21 and LDAR programs. The TVA2020 Toxic Vapor Analyzer is equipped with an FID to measure organic compounds with high sensitivity. The FID technology allows for a wide dynamic and linear range that produces stable and repeatable responses. The analyzer can be configured with both FID and PID technology for simultaneous detection and enhanced analytical capabilities. This dual configuration is capable of producing a more rapid reading of organic and inorganic compounds as opposed to a single detector technology and provides more comprehensive gas coverage than comparable size PID analyzers and FID analyzers.

After performing a primary calibration (calibration kit available), the TVA2020 Analyzer can be customized by activating internal logging parameters, uploading a monitoring route, establishing a bluetooth connection, setting alarm levels, and activating response factors.

Certifications

  • USA: Class I, Division 1, Groups A,B,C,D T3
  • Canada: Class I, Zone 1, Ex d ib IIC T3 Gb
  • ATEX: CE0359 Ex II 2 G Ex d ib IIC T3 Gb
  • IECEx: Ex d ib IIC T3 Gb
Specifications

Specifications

±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm
Lithium Ion
USB port, Windows XP operating system or higher
Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable
10.2 cm
Flame Ionization Detector (FID)
1 L/min., nominal at sample probe inlet
99.99% H2 for FID
29.2 cm
±2% at 500 ppm of methane
USB
-10°C to 45°C
One year from date of shipment
22.9 cm
10 hours at 0°C
USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb
0 to 30,000 ppm (methane)
4 in.
0.5 ppm of methane
Most Organic and Inorganic Compounds
50/60 Hz
11.5 in.
Minimum 10 hours
Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane
14°F to 113°F
120 V
9 in.