Promotional price valid on web orders only. Your contract pricing may differ. Interested in signing up for a dedicated account number?
Learn More

OPTIZYME™ HindIII, Fisher BioReagents™

 View more versions of this product

Catalog No. BP8006-1

Item Discontinued This item has been discontinued by Fisher Scientific. Please to view product availability in your area.


Description

Description

5'...A^A G C T T...3'
3'...T T C G A^A...5'

Supplied with: 10X OPTIZYME Buffer 5
Conditions for 100% Activity:

  • 1X OPTIZYME Buffer 5: 10mM Tris-HCl (pH 8.5 at 37°C), 10mM MgCl2, 100mM KCl and 0.1mg/ml BSA
  • Incubate at 37°C
Enzyme Activity in OPTIZYME buffers:
  • Buffer 1: 0 - 20%
  • Buffer 2: 20 - 50%
  • Buffer 3: 0 - 20%
  • Buffer 4: 50 - 100%
  • Buffer 5: 100%
Storage Buffer:
10mM Tris-HCl (pH 7.5 at 25°C), 250mM KCl, 1mM DTT, 0.1mM EDTA, 0.2mg/ml BSA and 50% (v/v) glycerol
Ligation and Re-cleavage:
More than 95% of the DNA fragments can be ligated and recut after a 50-fold over-digestion with HindIII.
Digestion of Agarose-embedded DNA:
A minimum 5 units of HindIII is required for the complete digestion of 1μg of agarose-embedded lambda DNA in 16 hours.
Methylation Effects:
Dam: Never overlaps - no effect
Dcm: Never overlaps - no effect
CpG: Never overlaps - no effect
EcoKI: Never overlaps - no effect
EcoBI: May overlap - cleavage impaired
  • 5'...TGm6AAGCTT(N)3 TGCT...3'
  • 3'...AC TTCGAA(N)3m6ACGA...5'
  • (Cleavage is impaired)
  • TRUSTED_SUSTAINABILITY
    Specifications

    Specifications

    10 U/μL
    37°C
    10mM Tris HCl (pH 7.5 at 25°C), 250mM KCl, 1mM DTT, 0.1mM EDTA, 0.2mg/mL BSA, 50% Glycerol
    7500 U
    HindIII
    25 to 50% Water, >50% Glycerin, 1 to 2.5% Potassium Chloride
    >95% of DNA fragments can be ligated and re-cut after 50-fold over-digestion with HaeIII
    Keep container tightly closed
    A.AGCTT
    Liquid
    Product Suggestions

    Product Suggestions

    SDS
    Documents

    Documents

    Product Certifications
    Promotions

    Promotions

    Provide Content Correction

    We continue to work to improve your shopping experience and your feedback regarding this content is very important to us. Please use the form below to provide feedback related to the content on this product.

    Product Title

    By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.

    Cancel Submit