Learn More
Labconco™ Precise™ Controlled Atmosphere Glove Boxes
Provide leak-tight environment for contamination-sensitive materials
Supplier: Labconco™ 5220100
Alert:
Desired Oxygen/Moisture Level: The more oxygen-sensitive the work, the lower the oxygen level required. Oxygen levels below 1% (10,000ppm) may be achieved with oxygen and moisture-removal columns. Maintaining levels as low as 1ppm requires a regenerative drying train accessory.
Includes:
- Pair of neoprene gloves (size 9.75, 30 in. [76cm] long, 15mil gauge)
- 22w fluorescent lamp and control switch
- Interior ceiling-mounted electrical duplex receptacle and switch with 5A (115V model)
Requires : Support base (10-358-108, -109; order separately) vacuum source for purging, and inert gas for filling. Contact your Fisher Scientific Representative for assistance.
Description
Ideal for procedures requiring low levels of oxygen (<5ppm) or moisture (<50ppm) such as work with organometallics, alternative energy cells, or hydrophilic chemicals.
Performance
- Meet Class 1 atmosphere containment conditions for oxygen leak rates per ISO 10648-2
- Performance-tested to maintain <5ppm oxygen/<50ppm moisture levels
- One-piece molded, medium-density polyethylene shell
- Dry epoxy-coated steel superstructure, transfer sleeve and interior shelf
- Inner and outer transfer chamber doors are pivoted, counterbalanced and equipped with quick-release latches
- Black, chemical-resistant phenolic core work surface sealed to box floor
- Nominal 13 cu. ft. interior space in main chamber
- 0.25 in. thick removable, laminated safety glass viewing window with neoprene gasket
- Automatic pressure relief valve activates at ±6 in. of water gauge
- Six manual valves with 0.37 in. compression fittings and hose barbs: Main chamber, 4 (2 purge/fill, 2 drying); Transfer chamber: 2 purge/fill
- Main chamber pressure gauge calibrated from -5 to +5 of water gauge
- Transfer pressure chamber gauge from 0 to -.29 in.Hg
- Light and electrical receptacle switches
Order Info
Dimensions Main chamber: 27.5D x 33.5W x 25 in.H (70 x 85 x 64cm); Transfer chamber: 11 nominal I.D. x 12 in.L (28 x 30cm); Window: 26.37W x 12.5 in.H (67 x 32cm); Pressure relief valve: 4 in. nominal dia. (10.2cm); Overall: 31.62D x 52.75W x 40 in.H (80 x 134 x 102cm); Shipping weight: 260 lb. (118kg)
Certifications
ETL listed
Compliance
Meets Class 1 atmosphere containment conditions per ISO 10648-2 test method.
Specifications
Glove Box | |
UL, ETL, CAN/CSA | |
27.5 in. | |
70 cm | |
40 in. | |
102 cm | |
Polyethylene | |
115 V | |
118 kg | |
33.5 in. | |
85.09 cm |
8 A | |
31.6 in. | |
80 cm | |
Procedures requiring low levels of oxygen (<5ppm) or moisture (<50ppm) such as work with organometallics, alternative energy cells or hydrophilic chemicals | |
25 in. | |
60 Hz | |
2 | |
260 lb. | |
57.2 in. | |
147 cm |
We continue to work to improve your shopping experience and your feedback regarding this content is very important to us. Please use the form below to provide feedback related to the content on this product.